Komatsu D37EX-24 Operation & Maintenance Manual page 153

Bulldozer
Table of Contents

Advertisement

OPERATION
Power source outside cab
24 V power supply
NOTICE
Do not use this as a power supply for 12 V equipment.
This will cause failure of the equipment.
Do not install equipment which exceeds 120 W (24 V x
5 A).
Open the hydraulic tank inspection cover on the left side of the
machine, and the connector (3) for taking out auxiliary power
supply is seen.
(Connector AUX1 can be used.)
FUSE
NOTICE
When replacing the fuse, be sure to turn the starting switch to OFF position and, after confirming that
the system operating lamp is not lit, set the battery disconnect switch key to OFF position.
The fuses protect the electrical component and wiring from burning out.
If the fuse becomes corroded, or looks white powdery, or the fuse is loose in the fuse holder, replace the
fuse.
Replace the fuse with the one of the same capacity.
Remove fuse box cover (1) under the left side of the operator's
seat, and fuse boxes (A) and (B) are seen.
Fuse box (C) is installed to the overhead panel.
EXPLANATION OF COMPONENTS
3-95

Advertisement

Table of Contents
loading

This manual is also suitable for:

D37px-2485001

Table of Contents