Komatsu D37EX-24 Operation & Maintenance Manual page 267

Bulldozer
Table of Contents

Advertisement

OPERATION
METHOD FOR REMOVING AND INSTALLING BATTERY
Stop the engine, and turn the starting switch and the battery disconnect switch keys to OFF positions
when handling the battery.
Prepare wooden blocks.
1.
Open the hydraulic tank inspection cover (1).
2.
Turn the battery disconnect switch to OFF position (O).
3.
Remove the clips (2) (2 places) from the hydraulic tank.
4.
Remove the bolts (3) (2 pieces) and remove the reservoir
tank (4).
Put the removed reservoir tank on the track.
5.
Remove the wing bolts (5) (2 pieces) and remove the vinyl
cover (6).
k
k
WARNING
TROUBLES AND ACTIONS
3-209