June 10th, 1997
Service Call Conditions
At power on
If there is any problem with the thermistor.
(This detection is also done when the machine comes
back to the normal mode from the Power Saver Mode
Level 2.)
If the fusing temperature stays below 70 °C for more
Standby mode
than 36 seconds when power saver standby
temperature (80 °C) is selected in Power Saver Mode
Level 1.
If the fusing temperature takes more than 60 seconds to
reach 150 °C from the standby temperature.
Either: If the fusing temperature stays above 110 °C for
more than 36 seconds when the power saver standby
temperature of 80 °C is selected for Power Saver Mode
Level 1.
Or: If the fusing temperature stays above 175 °C for
more than 36 seconds when the power saver standby
temperature of 145 °C is selected for Power Saver Mode
Level 1.
If the fusing temperature stays above 190 °C for more
During printing
than 60 seconds.
If the fusing temperature comes below 140 °C during
printing.
After printing
If the fusing temperature takes more than 20 minutes to
go down to below 100 °C when the machine goes into
the Power Saver Mode Level 2. (When fusing lamp OFF
is selected for Power Saver Mode Level 2.)
Either: If the fusing temperature takes more than 20
minutes to go down to below 100 °C when the machine
goes into the Power Saver Mode Level 2 (when the
power saver standby temperature of 80 °C is selected
for Power Saver Mode Level 2.)
Or: If the fusing temperature takes more than 20 minutes
to go down to the standby temperature (145 °C) when
the standby temperature is selected for Power Saver
Mode Level 1.
At any time
If the fusing temperature reaches 250°C.
DETAILED SECTION DESCRIPTIONS
Conditions
2-39
PRINTING
Error Code
(9-22)
Sub-code 09
Sub-code 05
Sub-code 02
Sub-code 0A
Sub-code 01
Sub-code 07
Sub-code 03
Sub-code 04
Sub-code 08