Ricoh Aficio FX10 Service Manual page 118

Hide thumbs Also See for Aficio FX10:
Table of Contents

Advertisement

June 10th, 1997
Communication Switch 0D
No
FUNCTION
The amount of remaining
memory below which
ringing detection (and
0
to
therefore reception into
7
memory) is disabled
Communication Switch 0E
No
FUNCTION
Minimum interval between
0
automatic dialing attempts
to
7
Communication Switch 0F - Not used (do not change the setting)
Communication Switch 10
No
FUNCTION
Memory transmission:
0
Maximum number of dialing
to
attempts to the same
7
destination
Communication Switch 11 - Not used (do not change the setting)
Communication Switch 12
No
FUNCTION
Memory transmission:
0
Interval between dialing
to
attempts to the same
7
destination
Communication Switch 13 - Not used (do not change the setting)
SERVICE TABLES AND PROCEDURES
COMMENTS
00 to FF (Hex), unit = 2 kbytes
(e.g., 0C(H) = 24 kbytes)
One page is about 24 kbytes.
If this setting is kept at 0, the machine will detect
ringing signals and go into receive mode even if there
is no memory space left. This will result in
communication failure.
COMMENTS
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine waits
before it dials the next destination.
COMMENTS
01 - FF (Hex) times
COMMENTS
00 - FF (Hex) minutes
4-33