Ricoh Aficio FX10 Service Manual page 55

Hide thumbs Also See for Aficio FX10:
Table of Contents

Advertisement

DETAILED SECTION DESCRIPTIONS
PRINTING
3. Paper Size and Paper End Detection
Standard Cassette
When the cassette runs out of paper,
the paper end sensor actuator [A]
drops through a slot in the bottom plate.
Selectable cassette paper sizes: A4,
Letter (by the user function)
The paper size sensor is not installed
for the standard cassette.
Refer to the Operation's Manual for
how to set paper size (Function 34).
Bypass Feed Slot
This machine does not detect paper width when the bypass feed slot is used.
The maximum feed length for bypass feed is 600 mm. The minimum feedable
paper size is 100 mm (width) and 148 mm (length).
Optional Cassette
The paper size detector [B] is located at the right hand side of the optional
cassette.
When the optional cassette runs out of paper, the paper end sensor actuator
[C] drops through a slot in the bottom plate.
The paper width sensor actuator [D] drops through a slot to detect paper
width.
[B]
[D]
2-26
June 10th, 1997
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
H523D516.wmf
[C]
H523D518.wmf