Ricoh Aficio FX10 Service Manual page 125

Hide thumbs Also See for Aficio FX10:
Table of Contents

Advertisement

SERVICE TABLES AND PROCEDURES
NCU PARAMETERS
4.3. NCU PARAMETERS
The following tables give the RAM addresses and units of calculation of the
parameters that the machine uses for ringing signal detection and automatic
dialing. The factory settings for each country are also given. Most of these
must be changed by RAM read/write (Function 06), but some can be
changed using NCU Parameter programming (Function 08); if Function 08
can be used, this will be indicated in the Remarks column. The RAM is pro-
grammed in hex code unless (BCD) is included in the Unit column.
Address
Country code for NCU parameters
807F00
Line current detection time
807F01
807F02
Line current wait time
807F03
Line current drop detect time
Function
4-40
Unit
Remarks
Use the Hex value to program the
country code directly into this address, or
use the decimal value to program it
using Function 08 (parameter CC).
Country Decimal
France
00
Germany
01
UK
02
Italy
03
Austria
04
Belgium
05
Denmark
06
Finland
07
Ireland
08
Norway
09
Sweden
10
Switzerland
11
Portugal
12
Holland
13
Spain
14
Israel
15
USA
17
Asia
18
Hong Kong
20
South Africa
21
Australia
22
New Zealand
23
Singapore
24
Malaysia
25
China
26
Taiwan
27
Turkey
32
Greek
33
20 ms
Line current is not detected
if 807F01 contains FF.
June 10th, 1997
Hex
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
11
12
14
15
16
17
18
19
1A
1B
20
21

Advertisement

Table of Contents
loading