Ricoh Aficio FX10 Service Manual page 40

Hide thumbs Also See for Aficio FX10:
Table of Contents

Advertisement

June 10th, 1997
Charger Leak Detection:
The machine detects a charger leak error when the FCU CN21-8 stays low
for 3 seconds or more (6 seconds or more at power on) either while in
standby mode or while the corona wire is being charged. When this occurs,
the machine warns the customer by lighting the Call Service indicator (error
code 9-17).
Charge Control
Power
Pack
-698V
In this machine, a higher corona wire current is used to counter black bands
on copies. The charge on the drum exceeds the zener diode voltage as a re-
sult of this higher current.
24VPP
21-1
Leak Signal
21-8
Charge
21-3
2-11
DETAILED SECTION DESCRIPTIONS
Fusing Unit Cover
Interlock Switch
ON/OFF
IC8
EXIO
QA1
Power
Pack
Driver
PRINTING
FCIP2
FCU
H523D505.wmf