IF THE FAN MOTOR DOES NOT MOVE:
Procedure
Check:
1. Fuse (main)
2. Battery
3. Main switch
4. Radiator fan motor
1. Fuse (main)
Refer to "CHECKING THE SWITCH".
2. Battery
• Check the battery condition. Refer to
"CHECKING AND CHARGING THE BATTERY"
in chapter 3
Open-circuit voltage:
12.8 V or more at 20 °C (68 °F)
3. Main switch
Refer to "CHECKING THE SWITCH".
ELECTRICAL COMPONENTS
CONTINUITY
CORRECT
CORRECT
5. Thermo switch 3
6. Wiring connection(the entire cooling system)
1NOTE:
Remove
the
troubleshooting.
1. Console
2. Front frame
3. Front pedal
• Use special tool(s) for troubleshooting.
NO CONTINUITY
Replace the fuse.
INCORRECT
• Clean the battery terminals.
• Recharge or replace the battery
INCORRECT
Replace the main switch.