ELECTRICAL COMPONENTS
• Set the pocket tester to "0" before starting
the test.
• The pocket tester should be set to the "Ω ×
1" range when testing the switch for
continuity.
• Turn the switch on and off a few times when
checking it.
- 304 -

CHECKING THE SWITCH

CHECKING THE SWITCH
Use a pocket tester to check the terminals for
continuity. If the continuity is faulty at any point,
replace the switch.
NOTE:
The terminal connections for switches (main
switch, light switch, etc.) are shown in a chart
similar to the one on the left. This chart shows
the switch positions in the column and the switch
lead colors in the top row.
For each switch position, "
terminals with continuity.
The example chart shows that:
①There is continuity between the "Red and
Brown/Blue" leads when the switch is set to