Hisun HS700UTV-4 Maintenance Handbook page 139

Hide thumbs Also See for HS700UTV-4:
Table of Contents

Advertisement

MAINTENANCE AND ADJUSTMENT OF THE UTV
YES
Charge
the
battery
charging voltage reaches 15 V.
Leave the battery unused for more than 30
minutes
before measuring its open-circuit
voltage.
12.8 V → Charging is complete.
12.0 ~ 12.7 V → Recharging is required.
Under 12.0 V → Replace the battery
Measure the open-circuit voltage
prior to charging.
Connect a charger and ammeter to
the battery and start charging.
I
s the amperage higher than the
standard
charging
written on the battery?
until
the
NOTE:
Set the charging time to a
maximum of 20 hours.
- 126-
Charging method using a constant voltage
charger
NOTE:
Leave the battery unused for more than 30
minutes before measuring its open-circuit
voltage.
amperage
This type of battery charger cannot
charge an MF battery. A variable
voltage charger is recommended.