FLUEING ARRANGEMENT FOR VERTICAL TERMINATIONS

Vertical Venting with One(1) 90
The shaded area in the diagram shows all allowable combinations
of straight vertical and offset to vertical terminations, using two
45
elbow, with Rigid Pipe Flueing Systems.
o
Flue must be supported at offsets.
Minimum distance between elbows is 305mm.
Maintain clearances to combustibles as listed in the
"Clearances" section in the manual.
Horizontal flue must be supported every 1M.
Refer to the "Flue Restrictor Position" section for
details on how to change the flue restrictor from the
factory setting of Set 0 or Set 3 if required.
Note: For ULPG Flue Restrictor - Set to "0" - 75mm
open.
24
Elbows (1 - 90
2 - 45
o
o =
)
o
Res trictor Set #3
18mm open
Metres
NOTE: FOR ULPG
FLUE RESTRICTOR
SET to "0" - 75MM OPEN
Regency GF900L-1 Gas Fireplace