Safety
TEMPERATURE SENSOR ALARM ACKNOWLEDGEMENT
Notice
The signal tone sounds again and again until the temperature returns to normal. Alternatively, switch off
the laser system and check the temperature sensors.
2.7.4
Emergency stop button
Pressing the emergency stop button immediately switches off the circuit.
The laser beam is interrupted and all movements are stopped.
The task of the emergency stop switch is:
First priority:
Prevention of danger to the operating personnel.
Second priority:
Prevention of damage or destruction of the machine and/or material.
ACKNOWLEDGE THE EMERGENCY STOP SWITCH
2.7.5
Interlock safety switches
Interlock safety switch query the closed status of the acrylic top lid, side panels and front door. If the safety devices are
open or not present, the laser cannot be operated. However, the pilot laser stays active.
20
Press any key on the keypad to acknowledge the alarm.
1. Turn the emergency stop switch counterclockwise to
unlock it so that the green marking is visible.
2. Restart the laser system using the key switch.