Operation
The compressed air connected to the Gas-Kit light must be dry and oil-free and may have a maximum of 10 bar at 150 lt/
min.
Caution
The maximum value at the pressure flow indicator must not exceed 0.4MPa. In case of non-compliance,
the tubing or lens may be damaged.
MAINTENANCE NOTE:
The filters of the Gas-Kit light (maintenance unit) must be checked regularly for liquid formation. This liquid would be
blown onto the material, reach the lens and contaminate it.
Check air pressure preparation!
Only connect dry and oil-free compressed air.
If you have any questions, please contact our experienced technical support in your area.
7.9.5
Trotec Vision Print&Cut
66
1. To adjust the air pressure, li the adjustment knob of the air
pressure regulator and turn it until the air pressure display shows
the desired value.
2. Lock the set pressure by pressing the adjustment knob downwards
again.
Notice
Turn the regulator to a maximum of 0.4 MPa.
The Vision option is a camera on the laser processing head
that reads the registration marks on the plate material, thus
detecting and compensating for distortions in the print.
The material is cut for an exact fit. Production times are
accelerated and cost-intensive miscuts are avoided.