Trotec Speedy 400 Operating Manual page 28

Hide thumbs Also See for Speedy 400:
Table of Contents

Advertisement

Technical Data
Caution
The laser may only be operated with properly installed and operating exhaust system. Damage to the
system, caused by the use of not any exhaust system or improper extraction equipment, will not be
covered by any liability.
The requirements for the exhaust system and recommended Trotec exhaust systems for standard applications depend
on the working table installed in the machine.
RECOMMENDED EXHAUST SYSTEMS:
Exhaust system
Atmos Duo Plus
Vent Set 400
Vent Set 500
Notice
Connection has to be carried out by our Technical Support.
Observe instructions for operation and maintenance according to the operating manual of the exhaust
system.
TECHNICAL DATA OF THE CORRESPONDING EXHAUST SYSTEMS:
Exhaust system
Hose connection ø [mm]
(inside diameter)
Atmos Duo Plus
70 / 70 / 45
Vent Set 400
100
Vent Set 500
100
REQUIREMENTS FOR THE EXHAUST SYSTEM:
Machine
Volume flow [m³/h]
Speedy 400
400
The monitoring point for flow rate and pressure is at the exhaust port at the laser machine. Pressure loss by hoses /
pipes or filter parts of the exhaust system has to be determined and additionally calculated when selecting a proper
exhaust system.
A powerful exhaust system keeps the lifetime of optics and mechanical components, the cutting quality and the laser
power interacting with the workpiece from being impaired by fumes and dust accumulating in the machine.
28
Speedy 400
✓ (without vacuum table)
Volume flow [m³/h]
(2x) 320
max. 1000
max. 1200
Pressure [Pa]
4200
Pressure[Pa]
8500 (230V)
max. 3800
max. 7000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8070