Emergency Stop Button (Only With Temperature Sensor Option); Interlock Switches; Side Panels; Acrylic Top Lid - Trotec Speedy 360 flexx Operation Manual

Hide thumbs Also See for Speedy 360 flexx:
Table of Contents

Advertisement

Speedy 360
2.7.4

Emergency stop button (only with temperature sensor option)

The emergency stop button, which is located above the operation panel, is present only if the machine
is equipped with an optional temperature sensor.
When pressing an emergency stop button, the electric circuit immediately shuts off. The laser beam is
interrupted, and all movements are stopped
The function of the emergency stop device is:
Firstly:
to prevent any risks to the operating personnel.
Secondly:
to avoid any damage to/destruction of the machine/material.
2.7.4.1 Emergency stop acknowledgement
2.7.5

Interlock switches

Interlock switches query the closed status of the acrylic top lid, side panels and front door.
If the safety devices are open or not present, the laser cannot be operated. However, the pilot laser
stays active.
2.7.6

Side panels

The side panels protect from laser light and must always be closed and properly attached.
2.7.7

Acrylic top lid

The type of acrylic top lid depends on the laser type. It protects the operator from uncontrolled
emission of laser radiation.
BA 8032_2.2_EN (05/2016)
1. Turn the emergency stop button to unlock it.
(green marker is visible)
2. Reboot the laser device to acknowledge the
laser fault.
www.troteclaser.com