Connecting:
1. When using an original Trotec exhaust system, also connect this, using the exhaust connection cable included, to
the exhaust cable connection on the laser.
2. Plug the ends of the exhaust hose into the exhaust nozzle that is intended for this purpose on the exhaust system
and on the laser. The position of the connector depends on the type of the exhaust system.
3. Plug in the mains cable of your exhaust system into the mains socket.
Follow the operation and maintenance instructions in the Manual of the exhaust system.
6.6.2

Chiller

WATER COOLING UNIT (CHILLER)
When using water-cooled laser sourced, a cooling unit is required. The mixture of destilled water and special additives
protects and prevent the formation of algae and limescale deposites in the cooling unit and laser source. This ensure
operation and longevity of the laser cooling unit and laser source
MIXTURE
Distilled water and the additive *Watertreatment-Kit 480-WTK-10.88.
Caution
Do NOT use glycol-containing addatives!
❶ Intake connector for exhaust hose
❷ Connector for exhaust connection cable
❸ Main cable to main socket
❹ Safety switch
Setup and installation