Mixing pump G 4 X FU 230/400V Overview - Operation
Cleaning the machine after work
47.9 Close motor tilt flange
2
1
Fig. 95: Close motor tilt flange
5
4
Fig. 96: Switching on
Fig. 97: Remove the mixing tube cleaner
47.10 Insert agitator
1
2
1
Fig. 98: Insert agitator
58
1. Close the motor tilt flange (1) and lock using the quick closure
(2).
2. Turn main switch (3) to position "I".
3. Press the green push button (4) control voltage "ON".
4. Switch on the machine, turn the selector switch of the pump
3
motor (5) clockwise.
5. Let the machine run for about 5 - 10 seconds until the mixing
tube has been cleaned.
6. Switch off the machine at the selector switch of the pump motor
(5) (position "0").
7. Turn main switch (3) to position "0".
8. Open the quick closure at the motor tilt flange and tilt the motor.
7
9. Take the mixing tube cleaner (6) and cleaning shaft (7) from the
6
mixing tube.
3
1. Insert agitator (1) and ensure correct positioning at the rotor
head (2).
2. When closing the tilt flange ensure that the agitator (1) engages
properly into the drive dog (3).
3. Close the quick closure at the mixing tube.
DANGER!
Risk of contusion at the motor tilt flange!
There is a risk of contusion when closing the motor
tilt flange.
Do not reach into the clamping area of the motor
tilt flange.
2020-01-07