Mixing pump G 4 X FU 230/400V Overview - Operation
Description of assemblies
10 Description of assemblies
10.1 Hopper
Fig. 6: Assembly unit hopper
10.2 Control cabinet article number 00 25 46 51
16
15
14
13
12
11
10
Fig. 7: Assembly unit control cabinet
14
The mixing pump PFT G 4 X consists of the following
main components:
Hopper with frame and protective grille
Control cabinet
1
1. Master switch is also emergency-stop switch
2
2. Push button water inlet
3
3. Selector switch water pump manual-0-automatic
4
4. Pilot lamp operation 400V
5. Pilot lamp operation 230V
6. Main terminal 32A
5
7. **Schuko socket outlet 230V, controlled for water pump
6
8. Schuko socket outlet 230V, continuous current for air
compressor
9. Connection for gear motor
10. Dummy connector for remote-controlled power socket
7
11. Remote control socket.
8
12. Yellow pilot lamp, for wrong direction of rotation
9
13. Red pilot lamp, motor protection switch was triggered
14. Selector switch pump motor
15. Operation button machine ON / OFF (control voltage).
16. Selector switch star wheel
**NOTE!
Switch off the water pump in 230V / 16 A operation.
(16A fuses could trigger due to the power consumption
of the machine).
2020-01-07