Connection Of Power Supply (230V); Voltage 230V; Connecting The Power Supply 230V - PFT G 4 X FU Series Operating Manual

Mixing pump 230/400v
Hide thumbs Also See for G 4 X FU Series:
Table of Contents

Advertisement

43 Connection of power supply (230V)

43.1 Voltage 230V

1
Fig. 83: Voltage selector

44 Connecting the power supply 230V

1
2
2
Fig. 84: Connect power 230V
2020-01-07
Mixing pump G 4 X FU 230/400V Overview - Operation
Connection of power supply (230V)
1. Open control cabinet and turn voltage selector to 230V.
2. Turn the potentiometer (2) for the motor speed and/or the
material quantity to level 10.
2
3. Close again the control cabinet.
1. Connect adapter cable (1) to 230V AC network.
2. Connect the adapter cable (1) with the power cable (2) item
number 20423920 and connect to the machine.
Advantage: The motor speed can be controlled via
the potentiometer.
Disadvantage: As the machine is controlled via the
frequency converter, the gear motor no longer
reaches its full capacity (maximum 4 kW).
NOTE!
Further procedure as from check of the individual
connectors chapter 27.1.
DANGER!
Danger of death from electric current!
The connection line has to be fused
properly:
Connect the machine only to a power
supply with permissible RCCB 30 mA
RCD (residual current operated device)
type "B" all-current sensitive for operation
of frequency converters.