14 Intended use Control panel
14.1 Intended purpose control panel
14.2 Intended purpose solenoid valve
14.3 Intended purpose flow meter
2020-01-07
Mixing pump G 4 X FU 230/400V Overview - Operation
The tool is conceptualised and designed exclusively for the
purpose of use specified here.
Scope of application:
Primary use for water and neutral, non-adhesive
liquids.
Also suitable for air and neutral non-
flammable gases.
Maximum operating pressure (inlet pressure) 16
bar.
Outlet pressure infinitely adjustable from 1.5 to 6
bar.
Smallest possible inlet pressure 2.5 bar.
Minimum pressure drop (inlet pressure/outlet
pressure) 1 bar.
Maximum media and ambient temperature 75°C.
Assembly position as desired, preferable vertical.
Scope of application:
Solenoid valves for liquid and gaseous media,
aggressive or neutral, can be used different
temperature and pressure ranges
Type 6213 is a 2/2 way solenoid valve with straight
passage, normally closed, with a permanently
coupled membrane system. It operates from 0 bar
and can be used universally for liquids. A minimum
pressure differential of 0.5 bar is required for the
valve to fully open.
Scope of application:
The
flow
measurement of transparent liquid and gaseous
flows in closed pipelines. Optionally the devices
can be used for flow monitoring.
Intended use Control panel
meter
is
used
for
the
volume
19