Measures In Case Of Power Cut; Main Switch To Position "0; Relieve Mortar Pressure - PFT G 4 X FU Series Operating Manual

Mixing pump 230/400v
Hide thumbs Also See for G 4 X FU Series:
Table of Contents

Advertisement

Mixing pump G 4 X FU 230/400V Overview - Operation

Measures in case of power cut

40 Measures in case of power cut

40.1 Main switch to position "0"

2
Fig. 72: Selector switch position "0"

40.2 Relieve mortar pressure

2
1
Fig. 73: Check mortar pressure
44
1
1. Close the air tap at the spraying gun.
2. Turn the main switch (1) to position "0".
3. Turn the selector switch for the pump motor (2) to position "0".
4. Switch off the air compressor using the green toggle switch.
5. Let qualified personnel check the power supply.
1. Open the air tap at the spraying gun.
2. Check the mortar pressure gauge (1) if the mortar pressure has
lowered to "0 bar". If required relieve the mortar pressure by
lightly loosening the nuts (2). In doing so, cover the work area
with film.
3. Firmly tighten the nuts again.
4. Close the air tap at the spraying gun.
DANGER!
Overpressure on the machine!
When opening machine parts they can open in an
uncontrolled manner and injure the operator.
Open machine only when the pressure is at "0
bar".
DANGER!
Risk of injury from discharged mortar!
Discharged mortar may lead to injuries to eyes and
face.
Therefore:
Never look into the spraying device.
Always wear protective goggles.
Always position yourself in such a way that you
are not hit by the mortar being discharged.