Interruption Of Work; In Case Of Longer Interruption Of Work/Break; Switch Off Air Compressor - PFT G 4 X FU Series Operating Manual

Mixing pump 230/400v
Hide thumbs Also See for G 4 X FU Series:
Table of Contents

Advertisement

Mixing pump G 4 X FU 230/400V Overview - Operation
Apply mortar

37.2 Interruption of work

1
Fig. 66: Closing the air tap

37.3 In case of longer interruption of work/break

Fig. 67: Closing the air tap
Fig. 68: Switching off

37.4 Switch off air compressor

Fig. 69: Air compressor
42
1. Close the air tap (1) if you interrupt your work for a short while.
2. The machine stops.
3. Once you open the air tap (1), the machine will start-up again.
1
1. Close air tap (1).
2. Switch off the machine at selector switch of the pump motor (2)
(position "0").
2
1. Switch off the air compressor using the green toggle switch (1).
2. Open the air tap at the spraying gun.
1
NOTE!
Always observe the setting time of the material to be
processed:
Clean the system and mortar hoses depending on
the setting time of the material and the length of the
interruption (pay attention to outside temperature).
The guidelines of the material manufacturers have to
be observed regarding breaks.
DANGER!
Risk of injury from discharged mortar!
Discharged mortar may lead to injuries to eyes and
face.
Attention, residual pressure.