Mixing pump G 4 X FU 230/400V Overview - Operation
Connecting the power supply 400V
28.1 Check the individual connectors
Fig. 38: Power connections
28.2 Connecting the water supply
1
2
Fig. 39: Draining cocks
Fig. 40: Connecting the water
32
1
Connection of pump motor (1).
2
NOTE!
3
The booster pump is necessary should the water
pressure be less than 2.5 bar when the machine is
running.
Check connection of air compressor (2).
Check connection of pump motor (3).
WARNING!
Danger to life from rotating parts!
Improper operation may lead to serious damage to
persons or property.
The respective drive (motors) must be operated
only with the control cabinet of the machine.
1. Close the water draining cocks (1) at the water fitting.
2. Close the water sampling valve (2).
3. Clean the water hose (3) from the water supply and bleed.
4. Connect the water hose (3) to the water inlet (4).
NOTE!
Use only clean water free of solids. The minimum
pressure is 2.5 bar when the machine is running.
4
Pay attention to the Drinking Water Ordinance in
3
part 1.
2020-01-07