Sign In
Upload
Manuals
Brands
PFT Manuals
Music Mixer
G4X Super
PFT G4X Super Manuals
Manuals and User Guides for PFT G4X Super. We have
4
PFT G4X Super manuals available for free PDF download: Operating Manual, Operation Manual
PFT G4X Super Operating Manual (72 pages)
Mixing pump 230/400V
Brand:
PFT
| Category:
Water Pump
| Size: 5 MB
Table of Contents
Table of Contents
3
1 EC Declaration of Conformity
6
2 Examination
7
Examination by Machine Operator
7
Periodic Inspection
7
3 General Information
8
Information Regarding the Operating Manual
8
Keep the Manual for Future Reference
8
Division
8
Spare Parts Lists
8
4 Spare Part Lists
9
5 Technical Data
10
General Information
10
Power Connection
10
Operating Conditions
10
Power Values
11
Sound Power Level
11
Vibrations
11
6 Dimension Sheet
12
7 Name Plate
12
8 Quality Control Sticker
12
9 Assembly
13
Overview
13
10 Description of Assemblies
14
Hopper
14
Control Cabinet Article Number 00 25 46 51
14
Mixing Tube with Motor and Pump
15
Water Fitting
15
Air Compressor DELTA2 230V with Pressure Switch-Off
15
11 Connections
16
12 Operating Modes
16
Selector Switch Star Wheel
16
Selector Switch Pump Motor
16
Selector Switch Pressure Booster Pump
17
Voltage 230/400V Changing
17
13 Accessories
17
Adapter Cable
18
14 Intended Use Control Panel
19
Intended Purpose Control Panel
19
Intended Purpose Solenoid Valve
19
Intended Purpose Flow Meter
19
15 Intended Use Air Compressor
20
Intended Purpose Air Compressor
20
Safety Systems Air Compressor
21
Pressure Switch-Off Air Compressor
21
Dry-Running Air Compressor
21
16 Description PFT Booster Pump (Accessory)
22
Scope of Application Booster Pump
22
Intended Use
22
17 Preparation Booster Pump AV3 (Accessory)
23
18 Initial Start-Up Booster Pump
23
Start-Up Booster Pump
23
19 Description G 4 X FU 230/400V
24
Functional Principle G 4 X FU 230/400V
24
Functional Description G 4 X FU 230/400V
25
Fields of Application
25
20 Material
25
Flowability / Flow Characteristics
25
23 Transport, Packing and Storage
26
Safety Instructions for Transport
26
Transport Inspection
27
Transport
28
Transport with Van
28
Transport in Individual Parts
29
21 Mortar Pressure Gauge
26
22 Safety Rules
26
24 Packaging
29
25 Operation
30
Safety
30
26 Safety System
30
27 Preparing the Machine
31
28 Connecting the Power Supply 400V
31
Check the Individual Connectors
32
Connecting the Water Supply
32
Connection of Water from Water Tank
33
29 Switching on the G 4 X (400V)
34
Putting the Machine into Operation (400V)
34
Set Water Quantity
34
Soaking of the Mixing Section
35
30 Mortar Pressure Gauge
35
31 Hazardous Dusts
35
Anti-Dust Unit for G 4 Completely
36
32 Feeding Dry Material to the Machine
36
33 Monitoring the Machine
37
34 Putting the Machine into Operation
38
Check Consistency of Mortar
38
Start the Machine in a "Flying" Mode (400V)
38
35 Mortar Hoses
39
Prepare Mortar Hoses
39
Connect Mortar Hose
39
36 Compressed Air Supply
40
Connect Air Hose
40
Connecting the Spraying Gun
40
Switch on Air Compressor
40
37 Apply Mortar
41
Open the Air Tap at the Spraying Gun
41
Interruption of Work
42
In Case of Longer Interruption of Work/Break
42
Switch off Air Compressor
42
38 Remote Control
43
Working with the Remote Control
43
39 Stopping in Case of Emergency Emergency-Stop Switch
43
Emergency-Stop Switch
43
40 Measures in Case of Power Cut
44
Main Switch to Position "0
44
Relieve Mortar Pressure
44
41 Work on Troubleshooting
45
Reaction in the Event of Faults
45
Fault Displays
46
Faults
46
Safety
46
Table of Faults
47
Signs for Hose Blockages
49
Causes for this Can be
50
Earlier Damage to the Mortar Hose
50
42 Removal of Blockages in the Hose
50
Change the Direction of Rotation of the Mixing Pump Motor in Case of Blockages in the Hose (400V)
50
Change the Direction of Rotation of the Mixing Pump Motor in Case of Blockages in the Hose (230V)
51
Blockage Does Not Dislodge
51
Switch the Machine Back on after the Blockage Has Been Removed (400V)
52
Switch the Machine Back on after the Blockage Has Been Removed (230V)
52
43 Connection of Power Supply (230V)
53
Voltage 230V
53
44 Connecting the Power Supply 230V
53
46 Start the Machine in a “Flying”
54
45 Switching on (230V)
54
Putting the Machine into Operation (230V)
54
Start the Machine in a "Flying" Mode 230V
54
47 Cleaning the Machine after Work
55
Empty the Mixing Tube
55
Secure against Restarting
55
Cleaning the G 4 X
56
Decouple Mortar Hose
56
Clean Mortar Hose
56
Remove the Water Hose
57
Cleaning the Mixing Tube
57
Insert the Mixing Tube Cleaner
57
Close Motor Tilt Flange
58
Insert Agitator
58
Cleaning the Hopper
59
48 Changing the Pump / Cleaning the Pump
59
Fold up Mixing Tube
59
Clean Rubber Mixing Section
59
49 Switch off G 4 X
60
50 Measures in Case of Risk of Frost
60
Blow Dry Water Fitting
61
Switch on Air Compressor
61
51 Maintenance
62
Safety
62
Remove Connection Cable
63
Environmental Protection
63
Maintenance Plan
64
Maintenance Work
64
Adjust Locking Lever
66
Measures after Effected Maintenance
66
52 Disassembly
67
Safety
67
Disassembly
68
53 Disposal
68
54 Index
69
Advertisement
PFT G4X Super Operating Manual (72 pages)
Mixing pump smart
Brand:
PFT
| Category:
Water Pump
| Size: 11 MB
Table of Contents
Table of Contents
3
EC Declaration of Conformity
6
Examination
7
Examination by Machine Operator
7
Periodic Inspection
7
General Information
8
Information Regarding the Operating Manual
8
Keep the Manual for Future Reference
8
Division
8
Operating Manual
9
Spare Parts Lists
9
Brochures
10
Accesories
10
Flip Catalog
10
Technical Data
11
General Information
11
Power Connection
11
Operating Conditions
11
Power Values Pump Unit D6-3
12
Output Values Pump Unit D5-2.5
13
Output Values Pump Unit D8-2
13
Sound Power Level
13
Vibrations
13
Dimension Sheet
14
Name Plate
14
Quality Control Sticker
14
Assembly
15
Overview
15
Description of Assemblies
16
Hopper
16
Control Cabinet Item Number 00252527
16
Schaltschrank Artikelnummer 00671960
17
Mixing Tube with Motor and Pump
17
Water Tap
17
Air Compressor
18
Connections
18
Operating Modes
18
Selector Switch Star Wheel
18
Accessories
19
Intended Use Control Panel
20
Intended Purpose Control Panel
20
Intended Purpose Solenoid Valve
20
Intended Purpose Flow Meter
20
Intended Use Air Compressor
21
Intended Purpose Air Compressor
21
Safety Systems Air Compressor
22
General Positioning of the Air Compressor
22
Hot Surface of the Air Compressor
22
Description PFT Booster Pump (Accessory)
23
Scope of Application Booster Pump
23
Intended Use
23
Preparation Booster Pump (Accessory)
24
Initial Start-Up Booster Pump
24
Start-Up Booster Pump
24
Description G 4 X Smart
25
Functional Principle G 4 X Smart
25
Functional Description G 4 X Smart
26
Fields of Application
26
Material
26
Flowability / Flow Characteristics
26
Mortar Pressure Gauge
27
Safety Rules
27
Transport, Packing and Storage
27
Safety Instructions for Transport
27
Transport Inspection
28
Packaging
29
Transport
29
Transport in Individual Parts
30
Operation
30
Safety
30
Safety Device
31
EMERGENCY off Pushbutton
31
Safety System
32
Preparing the Machine
32
Connecting the Power Supply 400 V
32
Check the Individual Connectors
33
Connecting the Water Supply
33
Connection of Water from Water Tank
34
Switching on the G 4 X
34
Putting the Machine into Operation
34
Set Water Quantity
34
Water the Mixing Zone
35
Mortar Pressure Gauge
35
Hazardous Dusts
36
Anti-Dust Unit for G 4 Completely
36
Fill the Machine with Dry Material
36
Monitoring the Machine
37
Putting the Machine into Operation
38
Check Consistency of Mortar
38
Start the Machine in a "Flying" Mode
38
Mortar Hoses
39
Prepare Mortar Hoses
39
Connect Mortar Hose
39
Compressed Air Supply
40
Connect Air Hose
40
Connecting the Spraying Gun
40
Switch on Air Compressor
40
Apply Mortar
41
Open the Air Tap at the Spraying Gun
41
Interruption of Work
42
In Case of Longer Interruption of Work/Break
42
Switch off Air Compressor
42
Remote Control
43
Working with the Remote Control
43
Stopping in Case of Emergency Emergency-Stop Switch
43
Emergency-Stop Switch
43
Measures in Case of Power Cut
44
Main Switch to Position "0
44
Relieve Mortar Pressure
44
Work on Troubleshooting
45
Reaction in the Event of Faults
45
Fault Displays
46
Faults
46
Safety
46
Table of Faults
47
Signs for Hose Blockages
49
Causes for this Can be
50
Earlier Damage to the Mortar Hose
50
Removal of Blockages in the Hose
50
Change the Direction of Rotation of the Mixing Pump Motor in Case of Blockages in the Hose
51
Blockage Does Not Dislodge
51
Switch the Machine Back on after the Blockage Has Been Removed
52
Cleaning the Machine after Work
52
Empty the Mixing Tube
52
Secure against Restarting
53
Cleaning the G 4 X
53
Decouple Mortar Hose
53
Clean Mortar Hose
54
Remove the Water Hose
54
Cleaning the Mixing Tube
55
Insert the Mixing Tube Cleaner
55
Insert Agitator
56
Cleaning the Hopper
56
Changing the Pump / Cleaning the Pump
57
Fold up Mixing Tube
57
Adjusting the Pump
58
Switch off G 4 X
58
Measures in Case of Risk of Frost
59
Blow Dry Water Fitting
59
Switch on Air Compressor
60
Maintenance
60
Safety
60
When Working on and in the Control Box
61
Environmental Protection
62
Maintenance Plan
63
Maintenance Work
63
Safety Valve Air Compressor
65
Adjust Locking Lever
66
Measures after Effected Maintenance
66
Disassembly
67
Safety
67
Disassembly
68
Disposal
68
Index
69
PFT G4X Super Operation Manual (68 pages)
Brand:
PFT
| Category:
Music Mixer
| Size: 5 MB
Table of Contents
Table of Contents
3
1 EC Declaration of Conformity
6
2 Examination
7
Examination by Machine Operator
7
Periodic Inspection
7
3 General Information
8
Information Regarding the Operating
8
Manual
8
Keep the Manual for Future Reference
8
Division
8
Spare Parts Lists
8
4 Technical Data
9
General Information
9
Power Connection
9
Operating Conditions
9
Power Values Pump Unit D6-3
10
Power Values Pump Unit D6-4
10
Sound Power Level
11
Vibrations
11
5 Dimension Sheet
11
6 Name Plate
12
7 Quality Control Sticker
12
8 Assembly
13
Overview
13
9 Description of Assemblies
14
Hopper
14
Control Cabinet Item Number 00 25 46 66
14
Mixing Tube with Motor and Pump
15
Water Tap
15
Air Compressor K2 N with Pressure Switch-Off
15
10 Connections
16
11 Operating Modes
16
Selector Switch Star Wheel
16
Selector Switch Pressure Booster Pump
16
12 Accessories
17
13 Intended Use Control Panel
18
Intended Purpose Control Panel
18
Intended Purpose Solenoid Valve
18
Intended Purpose Flow Meter
18
14 Intended Use Air Compressor
19
Intended Purpose Air Compressor
19
Safety Systems Air Compressor
20
General Positioning of the Air Compressor
20
Hot Surface of the Air Compressor
20
15 Description G 4 X SUPER / G 4 XXL
21
Functional Principle G 4 X SUPER / G 4 X
21
Fields of Application
21
Functional Description G 4 X SUPER / G
21
16 Material
22
Flowability / Flow Characteristics
22
17 Mortar Pressure Gauge
22
18 Safety Rules
22
19 Transport, Packing and Storage
23
Safety Instructions for Transport
23
Transport Inspection
24
Transport
24
Transport with Van
24
Transport in Individual Parts
25
21 Operation
26
Safety26
26
20 Packaging
26
22 Safety System
27
23 System Monitoring
27
Idle-Running Protection
27
24 Preparing the Machine
28
25 Connecting the Power Supply
28
Check the Individual Connectors
29
26 Connecting the Water Supply
29
Close Water Draining Cocks
29
Connecting the Water Supply
30
Connection of Water from Water Tank
30
27 Switching on the G 4 X
31
Putting the Machine into Operation
31
Set Water Quantity
31
Soaking of the Mixing Section
32
28 Mortar Pressure Gauge
32
29 Hazardous Dusts
32
Anti-Dust Unit for G 4 Completely
33
30 Feeding Dry Material to the Machine
33
31 Monitoring the Machine
34
32 Putting the Machine into Operation
34
Check Consistency of Mortar
34
Start the Machine in a "Flying" Mode
34
33 Mortar Hoses
35
Prepare Mortar Hoses
35
Connect Mortar Hose
36
34 Compressed Air Supply
36
Connect Air Hose
36
Connecting the Spraying Gun
37
Switch on Air Compressor
37
35 Apply Mortar
37
Open the Air Tap at the Spraying Gun
38
Interruption of Work
39
In Case of Longer Interruption of Work/Break
39
Switch off Air Compressor
39
36 Remote Control
40
Working with the Remote Control
40
37 Stopping in Case of Emergency Emergency-Stop Switch
40
Emergency-Stop Switch
40
38 Measures in Case of Power Cut
41
Relieve Mortar Pressure
41
39 Work on Troubleshooting
42
Reaction in the Event of Faults
42
Fault Displays
43
Faults
43
Safety43
43
Table of Faults
44
Signs for Hose Blockages
46
Causes for this Can be
47
Earlier Damage to the Mortar Hose
47
40 Removal of Blockages in the Hose
47
Change the Direction of Rotation of the
48
Blockages in the Hose
48
Blockage Does Not Dislodge
48
Switch the Machine Back on after the Blockage Has Been Removed
49
41 Cleaning the Machine after Work
49
Empty the Mixing Tube
49
Plug Level Sensor
50
Secure against Restarting
50
Cleaning the G 4 X
50
Decouple Mortar Hose
51
Clean Mortar Hose
51
Remove the Water Hose
52
Cleaning the Mixing Tube
53
Insert the Mixing Tube Cleaner
53
Insert Agitator
54
Cleaning the Hopper
54
42 Changing the Pump / Cleaning the Pump
55
Fold up Mixing Tube
55
43 Switch off G 4 X
56
44 Measures in Case of Risk of Frost
56
Blow Dry Water Fitting
57
Switch on Air Compressor
57
45 Maintenance
58
Safety58
58
Remove Connection Cable
58
Environmental Protection
59
Maintenance Plan
59
Maintenance Work
60
Safety Valve Air Compressor
62
Adjust Locking Lever
62
Measures after Effected Maintenance
62
46 Disassembly
63
Safety63
63
Disassembly
64
47 Disposal
64
48 Index
65
Advertisement
PFT G4X Super Operating Manual (72 pages)
Mixing pump
Brand:
PFT
| Category:
Water Pump
| Size: 31 MB
Table of Contents
Table of Contents
3
General Information
5
Information Regarding the Operating Manual
5
Division
5
Display of Safety and Warning Notices
5
Keep the Manual for Future Reference
6
Name Plate
6
EC Declaration of Conformity
7
Quality Control Sticker
8
Intended Use
8
Purpose of Solenoid Valve
8
Purpose of Flowmeter
9
Intended Purpose of Booster Pump
9
Purpose of Air Compressor
10
Technical Data
12
General Information
12
Power Connection
13
Operating Conditions
13
Capacity Values, Pump Unit D 6-3
14
Capacity Values, Pump Unit D 6-4
14
Sound Power Level
14
Vibrations
14
Transport, Packing and Storage
15
Safety Instructions for Transport
15
Transport Inspection
16
Packaging
16
Crane Transport
17
Transport in Van
17
Transport in Individual Parts
17
Transporting a Running Machine
18
Description
19
Overview
19
Operating Principle G 4 X Super / G 4 X XL
20
Brief Description G 4 X Super / G
20
Fields of Application
20
Description of Assemblies
21
Material Hopper
21
Control Box Item No. 00254666
22
Mixing Tube with Motor and Pump
23
Water Manifold
23
Air Compressor
24
Mortar Pressure Gauge
24
Connections
24
Operating Modes
25
Accessories
26
Operation
28
Safety
28
Safety Rules
28
Monitoring the Machine
29
Hazardous Dusts
29
Safety System
30
System Monitoring
30
Mortar Pressure Gauge
30
Inspection by Machine Operator
31
Preparing the Machine
31
Risk of Injury from Running Star Wheel
31
Positioning Machine
31
Connecting the Power Supply
32
Connecting the Water Supply
32
Switching on the Machine
34
Mortar Hoses
35
Compressed Air Supply
36
Feeding Dry Material to the Machine
37
Shutdown in Case of Emergency
38
Putting the Machine into Operation
39
Checking the Mortar Consistency
39
Feeding Material to the Machine
39
Remote Control
40
Applying Mortar
40
Opening the Air Tap on the Spray Gun
41
Interruption of Work
41
In Case of Longer Interruption of Work / Break
42
Switching off the Air Compressor
42
Switching off the Machine
43
Action in Case of Power Failure
43
Discharging Mortar Pressure
44
Switching on the Machine Again after a Power Failure
44
Measures in Case of Risk of Frost
45
Blowing the Water Manifold Dry
46
Ending Work / Cleaning the Machine
47
Cleaning
47
Secure against Restarting
47
Deactivate Level Sensor
47
Emptying the Mixing Tube
48
Disconnecting and Cleaning the Mortar Hose
48
Connecting the Water Hose
49
Cleaning the Mixing Tube
50
Cleaning the Material Hopper
51
Reaction in the Event of Faults
52
Safety
52
Faults
52
Fault Displays
53
Table of Faults
54
Hose Blockages
56
Removal of Clogging in Hoses
57
Maintenance
60
Safety
60
Remove Connection Cable
61
Environmental Protection
61
Maintenance Plan
62
Maintenance Work
62
Implementation by a Service Technician
62
Air Filter Compressor
63
Plastic Screen in the Strainer
63
Strainer Screen in Pressure Reducer
64
Setting Value Pressure Switch Water
64
Setting Value Pressure Switch Air
64
Setting Value Pressure Switch Air Compressor
64
Pump
65
Adjusting the Locking Lever
66
Actions after Completed Maintenance
66
Periodic Inspection/Expert Inspection
66
Spare Parts Lists
67
Accessories
67
Disassembly
68
Safety
68
Disassembly
69
Disposal
70
Advertisement
Related Products
PFT G4X XL
PFT G 5 SUPER
PFT PFT G4
PFT G 54 E
PFT G 5 c FU 230V
PFT G 5 c FU
PFT Categories
Water Pump
Mixer
Construction Equipment
Industrial Equipment
Cutter
More PFT Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL