Switching On (230V); Putting The Machine Into Operation (230V); Start The Machine In A "Flying" Mode 230V - PFT G 4 X FU Series Operating Manual

Mixing pump 230/400v
Hide thumbs Also See for G 4 X FU Series:
Table of Contents

Advertisement

Mixing pump G 4 X FU 230/400V Overview - Operation

Switching on (230V)

45 Switching on (230V)

45.1 Putting the machine into operation (230V)

Fig. 85: Putting the machine into operation

46 Start the machine in a "flying" mode 230V

3
1
5
Fig. 86: Start the machine in a "flying"
mode 230V
54
NOTE!
To ensure smooth running of the machine it has to
be ensures that the adapter cable is connected on
the mains side (see fig.
1
1. Turn main switch (1) to position "I".
NOTE!
Further procedure as from "Set water quantity"
chapter 28.2.
1. Press the green push button (1) control voltage "ON".
2. Pilot lamp operation 230V (2) lights up.
3. Turn the selector switch (3) for the star wheel to the right.
4. Turn the selector switch (4) of the booster pump clockwise.
4
5. Switch on the machine, turn the selector switch of the pump
2
motor (5) clockwise.
NOTE!
Further procedure as from "Start the machine in a
"flying" mode, check material consistency" chapter
33.2.
).
84