35 Mortar hoses

35.1 Prepare mortar hoses

Fig. 58: Prepare mortar hose

35.2 Connect mortar hose

SKIPIF 1 < 0
2
1
Fig. 59: Connect mortar hose
Fig. 60: Switching on
2020-01-07
Mixing pump G 4 X FU 230/400V Overview - Operation
1. Connect the cleaner coupling (1) at the water extraction valve
2
(2).
2. Connect the mortar hose (3) at the cleaner coupling.
1
3. Open the water sampling valve (2) and water the mortar hoses.
3
4. More mortar hose and cleaner coupling again and separate.
5. Remove all the water from the mortar hose.
6. Pre-lubricate the mortar hose with about two litres of wallpaper
paste.
7. The wallpaper paste is mixed through the mortar hose with the
first mixing.
DANGER!
Never loosen the hose couplings as long as there
is pressure on the mortar hoses (check mortar
pressure gauge)! The mix could burst out under
pressure and result in serious injuries, especially
injuries to the eyes.
Torn off hoses can beat about and injure
bystanders!
1. Connect mortar hose (1) to the pressure flange (2).
NOTE!
Ensure
tightness of the couplings! Dirty couplings and
rubber seals are not watertight, and water might
leak
blockages.
2. Lay mortar hoses in large radius so that no kinks form in the
hoses.
3. Attach risers carefully in order to prevent them from tearing off
under their own weight.
4. Switch on the machine, turn the selector switch of the pump
motor (3) clockwise.
3
5. As soon as mortar emerges at the end of the mortar hose,
switch off the machine at the selector switch for the pump motor
(3) (Position "0").
clean
and
correct
under
pressure
inevitably
Mortar hoses
connection
and
leading
to
39