12.3 Selector switch pressure booster pump
Fig. 14: Operating modes water pump
12.4 Voltage 230/400V changing
Voltage selector
Fig. 15:
13 Accessories
Fig. 16: Injection hood
Fig. 17: Delivery hood
2020-01-07
Mixing pump G 4 X FU 230/400V Overview - Operation
The booster pump can be operated in three different operating
modes:
Selector switch position "0":
Water pump is switched off, e.g. if the water pressure is
continuously at 2.5 bar.
Selector switch right:
Water pump is running in sync with the mixing pump (automatic
mode).
Selector switch left:
The water pump runs continuously in position "manual" (e.g. for
cleaning the hoses).
Voltage selector 230V / 1 phase or 400V / 3 phase
Delivery state position of voltage selector - 400V.
Change voltage:
Turn main switch to position "0".
Select voltage selector 230V - 400V.
Turn main switch to position "I".
Press the push button control voltage "ON".
PFT injection hood E1 for G 4
(article number 20 60 02 13)
The PFT injection hood is used for feeding dry material to the
mixing pump using the PFT SILOMAT pneumatic conveying
system.
PFT delivery hood with off-load operation protection for G 4
(article number 20 60 05 00)
The PFT delivery hood is used for feeding dry material to the
mixing pump PFT G 4 directly from the silo / container. In case of
an empty alarm in the hopper, the mixing pump is switched of via
the remote control socket.
Accessories
17