Mixing pump G 4 X FU 230/400V Overview - Operation
Cleaning the machine after work
47.3 Cleaning the G 4 X
47.4 Decouple mortar hose
Fig. 89: Mortar pressure to "0" bar.
47.5 Clean mortar hose
Fig. 90: Clean mortar hose
56
ATTENTION!
Water can enter sensitive machine parts!
Before cleaning the machine cover all openings in
which no water must enter for safety and functional
reasons (e.g electric motors and control cabinets).
NOTE!
Do not direct the water jet on electrical parts, such as
gear motor or control cabinet.
1. Check at the mortar pressure gauge (1) if the mortar pressure is
at "0 bar".
DANGER!
Overpressure on the machine!
1
When opening machine parts they can open in an
2
uncontrolled manner and injure the operator.
Open machine only when the pressure is at "0
bar".
2. Loosen the cam lever (2) and decouple the mortar hose from
the mortar pressure gauge.
NOTE!
Mortar hoses and spraying device have to be
cleaned immediately after finishing work.
2
1. Connect the cleaner coupling (1) at the water extraction valve
1
(2).
3
2. Press the water saturated sponge ball (3) into the mortar hose
(4).
4
3. Connect the mortar hose (4) with the sponge ball to the cleaner
coupling (1).
2020-01-07