Media Gateway 1000E PRI Gateway Installation and Commissioning
• Yellow Alarm
Table 33: Parameters for T1 spans
Parameter
Line Code
Frame Mode
Yellow Alarm
LBO
d. For each E1 span, configure the parameters as described in
Parameters for E1 spans
Important:
For E1 spans on the E1/T1 card, the CRC4 parameter on the Web
interface is automatically overridden by the Call Server configuration
if a mismatch between the Web interface configuration and the Call
Server configuration exists.
Table 34: Parameters for E1 spans
Parameter
CRC4
Impedance
Shield Ground
e. To save the parameters, click Submit.
Configure ISDN E1/T1 trunks
Value
B8ZS
ESF
FDL
0–133 FT
on page 117.
Value
No
120 ohm
No—for 75 Ohm only