Overload Detection Setting - JLG TOUCAN 1010 Service Manual

Hide thumbs Also See for TOUCAN 1010:
Table of Contents

Advertisement

6
ELECTRICAL CONTROLS DEVICE

6.1 Overload detection setting

Check :
1- Place a 200 kg load evenly distributed on the
platform floor.
2- Position the Ground controls/Platform controls
selector switch to "Platform controls". Ensure
the lower emergency stop is not activated.
3- Apply a slight pressure F1 on the platform.
ç An acoustic alarm sounds.
ç The corresponding LED alarm lights up.
ç Every function is disabled from the platform
controls.
4- Position the "Ground controls"/"Platform
controls" selector switch to "Ground controls".
ç An acoustic alarm sounds.
ç Every function is disabled from the ground
controls.
5- Apply a slight traction force F2 on the platform.
ç The acoustic alarm stops.
52
200 kg
F1
F2
Setting :
1- Place a 200 kg load evenly distributed on the
platform floor.
2- Loosen the locknut of the setting screw.
3- Loosen the setting screw until the sensor is
activated and the acoustic alarm sounds.
4- Apply a slight traction force F2 on the platform.
The acoustic alarm should stop. If the acoustic
alarm does not stop, tighten slightly the setting
screw.
5- When the correct setting has been found,
tighten the locknut.
6- Follow steps 3 and 4 of the checking procedure
to verify the setting is correct.
T o ucan 1010
6
Platform floor
Lock nut
Setting screw
Overload sensor
Platform
support
Model
Révision 04-2006