6
ELECTRICAL CONTROLS DEVICE
Description of entries / outputs of the module :
Inputs
Outputs
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
N1
N2
N3
N4
N5
N6
N7
C1
C2
C3
Detection controls in neutral :
Drive movements
- When the movement control joystick for drive
and/or a steering control button is actuated :
ç Inputs [N1] and [N2] are in the same state
:
- 0 to 4 V if the control has not been
authorized- Led [LD1] off.
- 24 V if the control has been authorized -
Led [LD1] on.
ç LED [LD2] lights up.
ç LED [LD3] goes off.
Structure movements (except platform levelling)
- When a structure movement control switch is
actuated :
ç Inputs [N3] and [N4] are in the same state :
- 0 to 4 V if the control has not been
authorized- Led [LD1] off.
- 24 V if the control has been authorized- Led
[LD1] on.
ç LED [LD4] lights up.
Models
Toucan 1010
Edition 04-2006
Pin n°
Supply + 24V
15
Supply 0 V
16
Auxillary
11
Enable pedal (+)
12
12 Vcc regulated output
17
Supply "Enable" relay [K1] (-)
13
Supply "Enable" relay [K1] (+)
4
Supply "Pump Inhibit" function
3
Reset module 0 (V)
2
Reset module (24 V)
1
18
Detection drive movements in neutral
6
19
Detection structure movements in neutral (except levelling)
7
20
Detection platform levelling movements in neutral
8
Movement selection
5
Movement detection
23
Accelerator 100%
24
Supply to speed reduction relay (-)
25
Function
Combination of movements
- If at least two of the Input groups [N1 - N2], [N3
- N4] and [N5 - N6] are in the same condition :
ç The control is not authorized or the
authorization of the control in progress is
cancelled (Led [LD1] goes out in the case
where the authorization is cancelled).
ç Output [E8] goes to 24 V ("Pump Inhibit"
function of the controller actuated - see §
4.5 - and orange indicator on).
ç Led [LD5] lights up (indicates the state of
the output [E8]).
Detection of discharge indicator power
cut
When the power is cut out by the discharge indicator,
the input [E10] is no longer supplied : the controls
can no longer be enabled [RESET]. Input [E10] must
be supplied before input [E4] for the controls to be
authorized. The reset push button on the platform
control panel allows to "force" entry [E10] to 24 V ; it
must be actuated and held before the enable pedal is
depressed.
6
Remarks
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used