ELECTRICAL CONTROLS DEVICE
Description and parameters values for Toucan 1010 models.
Parameter
Description
Speed 1
Speed n°1 (variable)
Speed 2
Speed n°2 (variable)
Speed 3
Speed n°3 (variable)
Speed 4
Speed n°4 (variable)
Speed 5
Speed n°5 (variable)
Speed 6
Speed n°6 (variable)
Calibrator use as measuring instrument :
BATT V :
The measure of battery voltage can be done at any time,
even when the work platform is in operation, thus
enabling analysis, if necessary, of the battery voltage
fluctuations.
MOTOR V :
The measure of the motor voltage in operation enables
the determination, for a chosen speed, of the voltage to
be applied at the motor terminals. The value of this
voltage calculated in percentage of the battery voltage
determines the speed setting.
MOTOR AMP. :
The measure of the current at the motor enables the
determination of the current limit value to which the
controller must be set when the machine is driven on a
ramp.
TEMP °C :
The measure of the temperature enables the analysis of
the controller temperature increases, therefore the
operating conditions of the work platform.
Models
Toucan 1010
Edition 04-2006
Values
Unit Step
Groupe
Centrale
Bosch
Advanced
%
1%
45%
%
1%
45%
%
1%
45%
%
1%
50%
%
1%
80%
%
1%
100%
Comments
Mast lowering movement.
43%
Make-up flow to hydraulic wheel motor.
Jib lowering movement.
43%
Slewing movements.
43%
Drive in slow speed
50%
Jib raising movement.
80%
Mast raising movement
100%
Drive in high speed
6