JLG TOUCAN 1010 Service Manual page 75

Hide thumbs Also See for TOUCAN 1010:
Table of Contents

Advertisement

6
ELECTRICAL CONTROLS DEVICE
Typical values of the analogic input [E10]
The typical voltages indicated below can be measured
between the battery
and the pin 14 of the controller
connector. The connector must be plugged into the
controller socket.
Voltage = 7 to 9 V
ç Platform control panel or emergency control
panel selected. All controls in neutral.
3,5 V < Voltage < 4 V
ç Joystick at the very beginning of its course
(acceleration signal of the controller starts
to increase only when the voltage reaches
just under 3,5V. Above 3,5V, the calibrator
displays a signal of 0% - see § 4.5).
Voltage < 150 mV
ç Joystick at the end of its course (accelerator
on maximum : signal nearing 100% on the
calibrator - see § 4.5).
0,75 V < Voltage < 1,10 V
ç Voltage threshold for the automatic switch
to 3rd gear (
over (A 0,75 V voltage corresponds to a
signal near 80% on the calibrator. A 1,10
V voltage corresponds to a signal near 70%
on the calibrator - see § 4.5).
Models
Toucan 1010
Edition 04-2006
) after temporisation t1 is
Potentiometers adjustment
!
CAUTION
The course of the potentiometers used on the
electronic module is 3/4 turn. Do not attempt
to turn the setting screws more than their
cou rse allows. Use a screwd river of
appropriate dimension.
!
CAUTION
T he potentiometers settings must be
completed by a qualified personnel.
- Approximate adjustment :
Potentiometer P1 : Temporisation for switching to fast
gear (
) [t1]
Potentiometer P2 : Speed change threshold (
)
Potentiometer P3 : Temporisation for make up flow
and braking [t2]
NOTE
A small jerk occurs when the machine
switches from (
from (
) gear to (
-
P1
+
-
P2
+
-
P3
+
) gear to (
) gear or
) gear. .
6
/
75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toucan 1010 i

Table of Contents