ELECTRICAL CONTROLS DEVICE

6.8 Electronic modules

6.8.1 Controls verification module

F
:
UNCTION
- Authorization of the control movement execution if and only if the "Dead man" device (enable pedal) is actuated
before the control of the desired movement : the controls must be in neutral before the action on the enable
pedal.
- Surveillance of the "Dead man" device : if the enable pedal is kept actuated and no movement has been
controlled within a time scale of 5 seconds, the valid state of the controls is cancelled : the enable pedal must
be released and actuated again to be able to control a movement.
- Prohibition of the simultaneous control of a structure / drive / platform levelling movement.
- Authorization of restarting a drive movement without having to return the joystick to neutral once the enable
pedal has been released at the condition that the pedal is actuated again within 5 seconds.
- Detection of the power cut out by the battery discharge indicator.
Symbols used to represent the module's Inputs / Outputs on the machine's electrical schematic.
E
Inputs / Outputs for control validation.
x
N
Verification of controls condition (Detection of controls in neutral).
x
L
: The module is connected to the plug [CR10] of the electronic card of the platform control panel.
OCATION
Led 1 :
Movement authorization
Led 2 :
Drive movements
Led 3 :
Inverse of Led 2
Led 4 :
Structure movement
Led 5 :
Pump Inhibit
Led 6 :
Platform levelling
Led
Led
Led
5
3
2
68
Led
Led
4
6
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
T o ucan 1010
6
Led
1
Model
Révision 04-2006

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toucan 1010 i

Table of Contents