4.2.2 "Oldham-Hawker" charger
Power supply : 110VAC - 60Hz / 230VAC - 50Hz
- Adaptation to network voltage :
DANGER
Prior to any operation requiring charger
cover removal, th e battery must be
disconnected and the charger must be
unplugged from the AC outlet. Failure to do
so could result in death or serious injury to
personnel.
Connections on transformer inlet terminals block :
230 VAC - 50 Hz
- Protections :
- Single pole circuit breaker : 32 Amps.
- Output fuse : 100 Amps.
SIGNALLING
DEFAULT LED
Default LED lights up
?
Default LED flashes
?
28
BATTERY - CHARGER
110 VAC - 60 Hz
Jumpers
FAULT SIGNALLING CHART (CPIV models)
CURRENT LEDs INDICATOR
The first LED flashes
The 2nd LED flashes
The 3rd LED flashes
The 4th LED flashes
The 4 LEDs flash
NOTE
A spare output fuse is strapped inside the
charger cover.
A-
CP IV models
g
e
CP IV models panel
a.
Charger ON LED indicator (green).
b.
Second charging rate LED indicator (yellow).
c.
End of charge LED indicator (green).
d.
Ah applied into the battery : 4 LEDs (from the right
to the left : 100% - 75% - 50% - 25%).
e.
ON/OFF switch.
f.
Default led indicator (red).
g.
Circuit breaker.
CAUSE
Voltage still below 1,7 V per cell after 1 minute of
charge
Voltage still below 2,05 V per cell after 1 hour of
charge
Voltage per cell still below the required gazing
voltage after 10 hours of charge.
Charging safety time exceeded.
Charge interruption due to a power cut. Charge
will be resumed as soon as the power returns.
Voltage per cell 140% above the nominal values.