SPECIFICATIONS
88
WR2-Series
PQRY-P YSLM-A1
Model
Power source
Cooling capacity
(Nominal)
Power input
Current input
EER
Temp. range of
Indoor
cooling
Inlet water
Heating capacity
(Nominal)
Power input
Current input
COP
Temp. range of
Indoor
heating
Inlet water
Indoor unit
Total capacity
connectable
Model / Quantity
Sound pressure level
(measured in anechoic room)
Sound power level
(measured in anechoic room)
Refrigerant piping High pressure
diameter
Low pressure
Set Model
Circulating water Water fl ow rate
Pressure drop
Operating
volume range
Compressor
Type
Starting method
Motor output
Case heater
External fi nish
External dimension HxWxD
Protection
High pressure protection
devices
Inverter circuit (COMP.)
Compressor
Refrigerant
Type x original charge
Net weight
Heat exchanger
Water volume in
plate
Water pressure
Max.
Optional parts
Notes:
*1,*2 Nominal conditions
Cooling
Heating
*The ambient temperature of the heat source unit needs to be kept below 40ºCD.B.
*The ambient relative humidity of the heat source unit needs to be kept below 80%.
*The heat source unit should not be installed at outdoor.
*Be sure to mount a strainer (more than 50 meshes) at the water inlet piping of the unit.
*Be sure to provide interlocking for the unit operation and water circuit.
*Nominal condition *1,*2 are subject to JIS B8615-2.
*Due to continuing improvement, above specifi cation may be subject to change without notice.
*1
kW
kcal / h
*1 BTU / h
kW
A
kW / kW
W.B.
°C
*2
kW
kcal / h
*2 BTU / h
kW
A
kW / kW
D.B.
°C
dB <A>
dB <A>
mm (in.)
mm (in.)
PQRY-P450YLM-A1
m
3
/ h
7.20 + 7.20
L/min
120 + 120
cfm
4.2 + 4.2
kPa
m
3
/ h
4.5 + 4.5 ~ 11.6 + 11.6
Inverter scroll hermetic compressor
Inverter
kW
kW
Galvanized steel sheets
mm
1,450 x 880 x 550
in.
57-1/8 x 34-11/16 x 21-11/16
High pressure sensor, High pressure switch at 4.15 MPa (601 psi) High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Over-heat protection, Over-current protection
Over-heat protection
R410A x 6.0 kg (14 lbs)
kg (lbs)
217 (479)
plate type
L
MPa
Heat Source Twinning kit: CMY-Q200CBK
Joint: CMY-Y102SS/LS-G2, CMY-R160-J1
Indoor
Inlet water temperature
27ºCD.B./19ºCW.B.
30ºC (86ºF)
(81ºFD.B./66ºFW.B.)
20ºCD.B. (68ºFD.B.)
20ºC (68ºF)
PQRY-P850YSLM-A1
3-phase 4-wire 380-400-415 V 50/60 Hz
96.0
82,600
327,600
18.03
30.4-28.9-27.8
5.32
15.0~24.0°C (59~75°F)
10.0~45.0°C (50~113°F)
108.0
92,900
368,500
18.49
31.2-29.6-28.5
5.84
15.0~27.0°C (59~81°F)
10.0~45.0°C (50~113°F)
50~150% of heat source unit capacity
P10~P250/2~50
56
71.5
28.58 (1-1/8) Brazed
41.28 (1-5/8) Brazed
44
11.6
5.0
2.0
Pipe length
Level diff erence
7.5m (24-9/16ft.)
0m (0ft.)
PQRY-P400YLM-A1
7.20 + 7.20
120 + 120
4.2 + 4.2
44
4.5 + 4.5 ~ 11.6 + 11.6
Inverter scroll hermetic compressor
Inverter
10.7
Galvanized steel sheets
1,450 x 880 x 550
57-1/8 x 34-11/16 x 21-11/16
Over-heat protection, Over-current protection
Over-heat protection
R410A x 6.0 kg (14 lbs)
217 (479)
plate type
5.0
2.0
Heat Source Twinning kit: CMY-Q200CBK
Joint: CMY-Y102SS/LS-G2, CMY-R160-J1

Advertisement

loading

This manual is also suitable for:

S seriesWy seriesR2 seriesWr2 series