• Manage air conditioner usage conditions
Energy consumption of air conditioners can be displayed in an easy-to-understand manner using a web browser.
* The billing function requires a PI Controller and watt-hour meter with pulse transmitter (procured locally).
• Operable without a transmission line power supply unit
The EW-50E unit is equipped with a power supply function. Power supplied by a transmission line power supply unit is not necessary.
Since an outside power supply is not needed, self-sustained operation is possible even when the outdoor unit system is down.
(In cases where the power consumption factor exceeds 1.5, a power supply unit is needed.)
LAN
Web browser
Not required
Not required
Power supply unit
• Energy-saving control
With the addition of an energy-saving control license (optional product), the temperature setting can be automatically changed*
according to the room temperature around the air-conditioner unit to allow greater energy savings without sacrificing comfort.
* 1. With this function, the temperature setting can be changed in +2°C/4°F increments for cooling and -2°C/4°F increments for heating during a set time
interval. In cases where the intake temperature and the temperature setting are significantly different, exclusion from the energy-saving target is
possible.
• Functions
* The functions and speci cations are subject to change.
Item
Remarks
ON/OFF
Switches air conditioners and general equipment ON or OFF.
Operation mode switching
Switches to cool, dry, auto, fan, or heat operation. * Some modes are not available depending on the unit.
Changes the set temperature.
Room temperature setting
* Set temperature range varies depending on the indoor unit model.
Set temperature 0.5°C/1°F
The temperature can be set and displayed in 0.5°C/1°F increments.
increments
* With some unit combinations, the temperature is set in 1°C/1°F increments.
Fan speed setting
The fan speed can be set to 4 levels, 3 levels, 2 levels, or automatic. * Available fan speeds differ depending on the unit.
Air direction setting
Fixed swing in 5 levels or auto air direction can be set. * Available air directions differ depending on the unit.
It is possible to disable the ability to use local remote controllers to run or stop the operation mode, set temperature, filter sign reset,
wind speed, wind direction and timer operation.
Prohibition of local remote
* In the Lossnay group, only ON/OFF and filter reset can be disabled.
controller operation
* Disabling of the fan speed, air direction, and timer operation can be set for the AT-50B, PAR-33MA, PAR-U02MEDA,
and PAC-YT52CR models.
Room temperature display
Displays the suction temperature of the indoor unit.
Error display
Displays the current error content together with the address.
Today/weekly/weekly by season/yearly
Schedule operation
Setting content: ON/OFF, operation mode, set temperature, disable local remote controller, air direction/fan
Displays the power consumption* or operating hours. * Optional part required.
Energy management
Group operation is possible for free plan Lossnay units only.
Ventilator operation (solo)
* The above group operation mode includes auto ventilation, heat exchange, and normal ventilation.
Ventilator operation
Free plan Lossnay units and indoor units can be interlocked and operated together.
(interlocked)
* At this point, air volume can be operated, but the ventilation mode cannot be selected.
Using a level signal or pulse signal, it is possible to input the following:
Level signal: Emergency Stop Input, Batch ON/OFF, and Demand Input.
External input
Pulse signal: Batch ON/OFF or Operation Disable/Enable
(timer connection,
* Requires an external power supply and external I/O adapter (PAC-YG10HA) sold separately.
emergency stop input, etc.)
Only one input can be selected from the above inputs.
External output (error
Using the level signal, ON/OFF, and Error/Normal are output.
* Requires an external power supply and external I/O adapter (PAC-YG10HA) sold separately.
output, operation output)
Monitor/operation, failure, filter sign monitoring, schedule setting, interlocked control setting (option), energy-saving control setting
Web browser
(option), energy-saving peak cut setting (option), set temperature range restrictions, other
Filter sign reset
Filter reset
Centralized system transmission line: Connectable Recommended
Connectable location
Indoor and outdoor transmission line: Connectable
* Functions and specifications differ depending on the connected equipment and model.
* Electric energy can be proportionally divided using the EW-50E alone.
However, the apportioned electricity charge function requires an AE-200E or TG-2000A.
• Connectable equipment: CITY MULTI, HYBRID CITY MULTI
A Control Mr. Slim (Can be connected using an M-NET adapter or special outdoor unit)
Room air conditioner (Requires a system control interface or M-NET control interface)
Lossnay/OA Processing Unit
AI controller, PI controller, DIDO controller
EW-50E
M-NET
M-NET
CENTRALISED REMOTE CONTROLLER
: By group or multiple groups
• Notes
* 1. Some items do not support the multi group setting and display.
205