SPECIFICATIONS
100
S-Series
PUMY-P YKM4(-BS)
PUMY-P YKMD-A(-BS)
Model
Power source
Cooling capacity
(Nominal)
Power input
Current input
EER
Temp. range of
Indoor temp.
cooling
Outdoor temp.*3,*4
Heating capacity
(Nominal)
Power input
Current input
COP
Temp. range of
Indoor temp.
heating
Outdoor temp.
Indoor unit
Total capacity
connectable
Model /
Quantity
Sound pressure level
(measured in anechoic room)
Sound power level
(measured in anechoic room)
Refrigerant piping Liquid pipe
diameter
Gas pipe
FAN
Type x Quantity
Air flow rate
Motor output
External static press.
Compressor
Type x Quantity
Starting method
Motor output
External finish
External dimension HxWxD
Protection
High pressure protection
devices
Inverter circuit (COMP./FAN)
Compressor
Fan motor
Refrigerant
Type x original charge
Net weight
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer)
Defrosting method
Optional parts
Notes:
*1,*2 Nominal conditions
Indoor Outdoor Pipe length Level difference
Cooling
Heating
*3 10 to 52ºC D.B. [50 to 126ºF D.B.], when connecting following models: PKFY-P10/15/20/25/32VLM, PFFY-P20/25/32VKM, PFFY-P20/25/32VLE(R)M and PEFY-P25/32/40VMA3;
*4 -15 to 52ºC D.B. [5 to 126ºF D.B.], when using an optional air protect guide [PAC-SH95AG-E]. However, this condition does not apply to the indoor unit listed in*3.
*5 Cooling mode/Heating mode
*6 External static pressure option is available (30 Pa/3.1 mmH2O). To use this option, PAC-SJ71FM-E is needed.
*7 When connecting 7 indoor units via branch box, connectable CITY MULTI indoor units are 3; connecting 8 indoor units via branch box, connectable CITY MULTI indoor units are 2.
*8 At least two indoor unit must be connected when using branch box.
*9 139 (306), for PUMY-P200YKMD-A-BS
*Nominal condition *1,*2 are subject to ISO 15042.
*Due to continuing improvement, above specification may be subject to change without notice.
PUMY-P112YKM4 (-BS)
3-phase 380-400-415V 50Hz,
380V 60Hz
*1
kW
*1
BTU / h
kW
A
4.99-4.74-4.57, 4.99
kW / kW
W.B.
15.0~24.0°C(59~75°F)
D.B.
-5.0~52.0°C(23~126°F)
*2
kW
*2
BTU / h
kW
A
5.43-5.16-4.98, 5.43
kW / kW
D.B.
15.0~27.0°C(59~81°F)
W.B.
-20.0~15.0°C(-4~59°F)
50~130 % of outdoor unit
CITY MULTI
P10-P140/9
Branch box
*8
P15-P100/8
Mixed
Branch box
CITY MULTI
P15-P140/5
system
1 unit
*8
Branch box
P15-P100/5
Branch box
CITY MULTI
P15-P140/3 or 2 *7
2 units *8
Branch box
P15-P100/7 or 8 *7
*5
dB <A>
*5
dB <A>
mm (in.)
9.52(3/8)
mm (in.)
15.88(5/8)
Propeller Fan x 2
m
/min
3
L/s
cfm
kW
0.074 + 0.074
Scroll hermetic compressor x 1
kW
Galvanized Steel Sheet
Munsell No. 3Y 7.8/1.1
mm
1,338 x 1,050 x 330 (+40)
in.
52-11/16 x 41-11/32 x 13 (+1-9/16) 52-11/16 x 41-11/32 x 13 (+1-9/16) 52-11/16 x 41-11/32 x 13 (+1-9/16) 52-11/16 x 41-11/32 x 13 (+1)
High pressure Switch
Overcurrent detection, Overheat
detection (Heat sink thermistor)
Compressor thermistor,
Over current detection
Overheating, Voltage protection,
Overcurrent detection
R410A 4.8kg
kg (lbs)
125 (276)
Cross Fin and Copper tube
HIC circuit
Reversed refrigerant circuit
Joint: CMY-Y62-G-E
Header: CMY-Y64/68-G-E
Fan motor: PAC-SJ71FM-E
Air protect guide: PAC-SH95AG-E
Indoor
Outdoor
27ºC DB/19ºC WB
35ºC DB(95ºF DB)
(81ºF DB/66ºF WB)
20ºC DB(68ºF DB)
7ºC DB/6ºC WB(45ºF DB/43ºF WB)
and M-Series, S-Series, and P-Series type indoor unit.
PUMY-P125YKM4 (-BS)
3-phase 380-400-415V 50Hz,
380V 60Hz
12.5
14.0
42,650
47,768
2.79
3.46
5.84-5.55-5.35, 5.84
4.48
4.05
15.0~24.0°C(59~75°F)
-5.0~52.0°C(23~126°F)
14.0
16.0
47,768
54,592
3.04
3.74
6.31-6.00-5.78, 6.31
4.61
4.28
15.0~27.0°C(59~81°F)
-20.0~15.0°C(-4~59°F)
50~130 % of outdoor unit
capacity
capacity
P10-P140/10
P15-P100/8
P15-P140/5
P15-P100/5
P15-P140/3
P15-P100/8
49/51
50/52
69/71
70/72
9.52(3/8)
15.88(5/8)
Propeller Fan x 2
110
110
1,833
1,833
3,884
3,884
0.074 + 0.074
0 *6
0 *6
Scroll hermetic compressor x 1
Inverter
Inverter
2.9
3.5
Galvanized Steel Sheet
Munsell No. 3Y 7.8/1.1
1,338 x 1,050 x 330 (+40)
High pressure Switch
Overcurrent detection, Overheat
detection (Heat sink thermistor)
Compressor thermistor,
Over current detection
Overheating, Voltage protection,
Overcurrent detection
R410A 4.8kg
125 (276)
Cross Fin and Copper tube
HIC circuit
Reversed refrigerant circuit
Joint: CMY-Y62-G-E
Header: CMY-Y64/68-G-E
Fan motor: PAC-SJ71FM-E
Air protect guide: PAC-SH95AG-E
Pipe length
7.5m (24-9/16ft.)
7.5m (24-9/16ft.)
PUMY-P140YKM4 (-BS)
PUMY-P200YKMD-A (-BS)
3-phase 380-400-415V 50Hz,
3-phase 380-400-415V, 50Hz;
380V 60Hz
3-phase 380V, 60Hz
15.5
52,886
4.52
7.23-6.87-6.62, 7.23
10.16-9.65-9.30, 10.16
3.43
15.0~24.0°C(59~75°F)
15~24°C (59~75°F)
-5.0~52.0°C(23~126°F)
-5~52°C (23~126°F) *3
18.0
61,416
4.47
7.15-6.79-6.55, 7.15
9.80-9.31-8.98, 9.80
4.03
15.0~27.0°C(59~81°F)
15~27°C(59~81°F)
-20.0~15.0°C(-4~59°F)
-20~15°C(-4~59°F)
50~130 % of outdoor unit
50~130% of outdoor unit
capacity
P10-P140/12
P15-P100/8
P15-P140/5
P15-P100/5
P15-P140/3
P15-P100/8
51/53
71/73
9.52(3/8)
15.88(5/8)
Propeller Fan x 2
Propeller Fan x 2
110
1,833
3,884
0.074 + 0.074
0 *6
Scroll hermetic compressor x 1
Scroll hermetic compressor x 1
Inverter
3.9
Galvanized Steel Sheet
Galvanized Steel Sheet
Munsell No. 3Y 7.8/1.1
Munsell No. 3Y 7.8/1.1
1,338 x 1,050 x 330 (+40)
1,338 x 1,050 x 330 (+25)
High pressure Switch
High pressure Switch
Overcurrent detection, Overheat
Overcurrent detection, Overheat
detection (Heat sink thermistor)
detection (Heatsink thermistor )
Compressor thermistor,
Compressor thermistor,
Over current detection
Over current detection
Overheating, Voltage protection,
Overheating, Voltage protection
Overcurrent detection
R410A 4.8kg
125 (276)
Cross Fin and Copper tube
Cross Fin and Copper tube
HIC circuit
Reversed refrigerant circuit
Reversed refrigerant circuit
Joint: CMY-Y62-G-E
Header: CMY-Y64/68-G-E
Joint: CMY-Y62-G-E
Fan motor: PAC-SJ71FM-E
Header: CMY-Y64/68-G-E
Air protect guide: PAC-SH95AG-E
Level difference
0m (0ft.)
0m (0ft.)
22.4
76,400
6.22
3.60
25.0
85,300
6.00
4.17
capacity
P10-P200/12
P22-P100/8
P15-P200/5
P22-P100/5
P15-P200/3
P22-P100/8
57/61
-
9.52(3/8)
19.05(3/4)
134
2,233
4,732
0.20 + 0.20
0
Inverter
5.3
R410A 7.3kg
138(305)*9
-