SPECIFICATIONS
106
CMB-M V-J1
CMB-M V-JA1
CMB-P V-KA1
CMB-M V-KB1
J1 type
CMB-M V-J1
Model
Number of branch
Power source
Cooling
Power input
(220/230/240)
Heating
Cooling
Current input
(220/230/240)
Heating
External fi nish
Connectable outdoor/heat source unit capacity
Indoor unit capacity
connectable to 1 branch
External dimension HxWxD
Refrigerant piping diameter
To outdoor/heat source unit
Connectable unit capacity
P200
P250/P300
P350
To indoor unit
Field drain pipe size
Net weight
Sound power level
Rated operation dB <A>
(measured in anechoic
Defrost
room)
Sound pressure level
Rated operation dB <A>
(measured in anechoic
Defrost
room)
*15
Accessories
Notes:
1.Installation/foundation work, electrical connection work, insulation work, power source
switch, and other items shall be referred to the Installation Manual.
2.The equipment is for R410A refrigerant.
3.Install this product in a location where noise (refrigerant noise) emitted by the unit will
not disturb the neighbors.
(For use in quiet environments with low background noise, position the BC
CONTROLLER at least 5m away from any indoor units.)
4.Sound pressure/power level diff ers depending on the connected outdoor/heat source
unit capacity or operation condition.
The sound pressure/power level at the rated operation is the value of the cooling
mode.
5.The sound pressure/power level values were obtained in an anechoic room. Actual
sound pressure level is usually greater than that measured in anechoic room due to
ambient noise and defl ection sound.
6.The sound pressure level values were obtained at the location below 1.5m from the
unit.
CMB-M V-J1
CMB-M104V-J1
4
50 Hz
kW
0.067/0.076/0.085
0.054/0.061/0.067
kW
0.030/0.034/0.038
0.024/0.027/0.030
A
0.31/0.34/0.36
0.25/0.27/0.28
A
0.14/0.15/0.16
0.11/0.12/0.13
Galvanized steel plate (Lower part drain pan: Pre-coated galvanized sheets + powder coating)
*13
(Use optional joint pipe combining 2 branches when the total unit capacity exceeds P81.)
mm
250 x 596 x 476
in.
9-7/8 x 23-1/2 x 18-3/4
High press. pipe
Low press. pipe
15.88 (5/8) Brazed
19.05 (3/4) Brazed
mm(in.) O.D.
19.05 (3/4) Brazed
22.2 (7/8) Brazed
mm(in.) O.D.
19.05 (3/4) Brazed or
*14
28.58 (1-1/8) Brazed
mm(in.) O.D.
22.2 (7/8) Brazed
Liquid pipe
Indoor unit Model 50
Indoor unit Model 50
or smaller 6.35 (1/4)
or smaller 12.7 (1/2)
Brazed
Brazed
bigger than 50 9.52
bigger than 50 15.88
mm(in.) O.D.
(3/8) Brazed
(5/8) Brazed (19.05
(3/4), 22.2 (7/8) with
optional joint pipe
used.)
mm (in.)
O.D. 32 (1-1/4)
kg (lbs)
26 (58)
59
dB <A>
71
40
dB <A>
53
CMB-M V-JA1
CMB-P V-KA1
CMB-M106V-J1
6
1-phase 220-230-240 V
60 Hz
50 Hz
0.097/0.110/0.123
0.078/0.088/0.097
0.045/0.051/0.057
0.036/0.041/0.045
0.45/0.48/0.52
0.36/0.39/0.41
0.21/0.23/0.24
0.17/0.18/0.19
P200 to P350
Model P80 or smaller
250 x 596 x 476
9-7/8 x 23-1/2 x 18-3/4
High press. pipe
Low press. pipe
15.88 (5/8) Brazed
19.05 (3/4) Brazed
19.05 (3/4) Brazed
22.2 (7/8) Brazed
19.05 (3/4) Brazed or
28.58 (1-1/8) Brazed
22.2 (7/8) Brazed
Gas pipe
Liquid pipe
Indoor unit Model 50
Indoor unit Model 50
or smaller 6.35 (1/4)
or smaller 12.7 (1/2)
Brazed
Brazed
bigger than 50 9.52
bigger than 50 15.88
(3/8) Brazed
(5/8) Brazed (19.05
(3/4), 22.2 (7/8) with
optional joint pipe
used.)
O.D. 32 (1-1/4)
29 (64)
59
71
40
53
Drain Connection pipe, Washer, Tie band
7.The solenoid valve switching sound is 56 dB (sound pressure level) regardless of the unit
model.
8.Indoor units P100, P125, P140 can be connected to 1 branch. (In this case, cooling
capacity decrease a little.)
9.Refrigerant piping diameter for connection of plural indoor units with 1 branch shall be
referred to the Installation Manual.
10.This unit is not designed for outside installations.
11.When brazing the pipes, be sure to braze after covering a wet cloth to the insulation pipes
of the units in order to prevent it from burning and shrinking by heat.
12.The ambient relative humidity of the BC controller needs to be kept below 80%.
13.Indoor unit capacity connectable to 1 branch is changed depending on the indoor unit type
and connection method. Please refer to the Installation Manual for more information.
14.For the refrigerant pipe size, refer to Installation Manual of outdoor units/heat source units.
15.The sound pressure level measured by the conventional method in JIS for reference
purpose.
CMB-M V-KB1
CMB-M V-KB1
CMB-M V-KB1
CMB-M V-KB1
CMB-M108V-J1
8
60 Hz
50 Hz
0.127/0.144/0.161
0.102/0.115/0.127
0.060/0.068/0.076
0.048/0.054/0.060
0.58/0.63/0.68
0.47/0.50/0.53
0.28/0.30/0.32
0.22/0.24/0.25
250 x 596 x 476
9-7/8 x 23-1/2 x 18-3/4
High press. pipe
Low press. pipe
15.88 (5/8) Brazed
19.05 (3/4) Brazed
19.05 (3/4) Brazed
22.2 (7/8) Brazed
19.05 (3/4) Brazed or
28.58 (1-1/8) Brazed
22.2 (7/8) Brazed
Gas pipe
Liquid pipe
Indoor unit Model 50
Indoor unit Model 50
or smaller 6.35 (1/4)
or smaller 12.7 (1/2)
Brazed
Brazed
bigger than 50 9.52
bigger than 50 15.88
(3/8) Brazed
(5/8) Brazed (19.05
(3/4), 22.2 (7/8) with
optional joint pipe
used.)
O.D. 32 (1-1/4)
33 (73)
59
71
40
53
60 Hz
Gas pipe