Mitsubishi Electric Y Series Manual page 221

Hide thumbs Also See for Y Series:

Advertisement

Booster unit
PWFY-P100VM-E-BU
Model
Power source
Heating capacity (Nominal)
Power input
Current input
Temp. range of heating
Outdoor unit/Heat
source unit condition
Booster unit inlet water temp.
Connectable outdoor unit/
Total capacity
heat source unit
Model / Quantity
Sound pressure level (measured in anechoic room)
Diameter of refrigerant pipe
Liquid
Gas
Inlet
Diameter of water pipe
Outlet
Field drain pipe size
External finish
External dimension H × W × D
Net weight
Compressor
Type
Starting method
Motor output
Lubricant
Operation volume Range
Circulating water
High pressure protection
Protection on internal
circuit (R134a)
Inverter circuit (COMP)
Compressor
Refrigerant
Type × original charge
GWP
CO
equivalent
2
Control
Design pressure
R410A
R134a
Water
Drawing
External
Wiring
Standard attachment
Document
Accessory
Optional parts
Remark
Note:
*1Nominal heating conditions
<R2-Series>
Outdoor Temp. : 7°CDB/6°CWB (45°FDB / 43°FWB)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
Inlet water Temp. 65°C (149°F) Water flow rate 2.15m
*2Do not use refrigerant other than the type indicated in the manuals provided with the unit and on the nameplate.
- Doing so may cause the unit or pipes to burst, or result in explosion or fire during use, during repair, or at the
time of disposal of the unit.
- It may also be in violation of applicable laws.
- MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting
from the use of the wrong type of refrigerant.
*3These values are based on Regulation (EU) No.517/2014.
* Due to continuing improvement, the above specifications may be subject to change without notice.
* The unit is not designed for outside installations.
* Please don't use the steel material for the water piping material.
* Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 0°C (32°F) or less.
* Please always make water circulate or pull out the circulation water completely when not using it.
* Please do not use groundwater and well water.
* Install the Outdoor unit (R2-Series) in an environment where the wet bulb Temp. will not exceed 32°C (90°F).
* The water circuit must use the closed circuit.
* Please do not use it as a drinking water.
kW
*1
kcal / h
*1
BTU / h
*1
kW
A
W.B.
-
-
50 ~ 100% of outdoor unit/heat source unit capacity
PURY-(E)P•Y(S)NW-A1(-BS), PQRY-P•Y(S)LM-A1
dB <A>
mm (in.)
mm (in.)
mm (in.)
mm (in.)
mm (in.)
mm
in.
31-1/2" (30-15/16" without legs) × 17-3/4" × 11-13/16"
kg (lbs)
kW
m
/ h
3
High pressure sensor, High pressure switch at 3.60 MPa (601 psi)
Discharge thermo protection, Over-current protection
*2
*3
*3
t
MPa
MPa
MPa
Details on foundation work, duct work, insulation work, electrical wiring, power source
switch, and other items shall be referred to the Installation Manual.
<WR2-Series>
Inlet water Temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0m (0ft)
/h
Inlet water Temp. (for PWFY side) 65°C (149°F) Water flow rate 2.15m
3
PWFY-P100VM-E-BU
1 - phase 220 - 230 - 240V 50 / 60Hz
12.5
10,800
42,700
2.48
11.63 - 11.12 - 10.66
-20 ~ 32°C (-4~90°F) R2-Series
10 ~ 45°C (50~113°F) WR2-Series
10 ~ 70°C (50 ~ 158°F)
44
ø9.52 (ø3/8") Brazed
ø15.88 (ø5/8") Brazed
R3/4
Rc3/4
ø32 (1-1/4")
NO
800 (785 without legs) × 450 × 300
59 (131)
Inverter rotary hermetic compressor
Inverter
1.0
NEO22
0.6 ~ 2.15
Over-heat protection, Over-current protection
R134a × 1.1kg (0.50lb)
1,430
1.6
LEV
4.15
3.60
1.00
WKB94L762
WKE94C229
Installation Manual, Instruction Book
Strainer, Heat insulation material, Wire x 1 set
NONE
BTU / h =kW × 3,412
cfm
lbs
* The specification data is subject
/h
3
to rounding variation.
SPECIFICATIONS
221
Unit converter
=m
/ min × 35.31
3
=kg / 0.4536