Download Print this page

Mitsubishi Electric Y Series Manual page 151

Hide thumbs Also See for Y Series:

Advertisement

Wall-mounted type
PKFY-P VLM-E
PKFY-P VKM-E
• Technologies and functions
VLM
Sophisticated design matches any interior.
A design that matches any room interior (VLM model)
A sharp and simple form combines beauty and function. The simple square design harmonizes beautifully with the straight lines of the
walls, floor and ceiling. The white body color has been adopted to enhance the beauty and comfort of a room without disturbing its
atmosphere.
Previous models
PKFY-P VHM <P32−P50>
PKFY-P VBM <P15−P25>
New lineup
The broad lineup from P10 to P50 offers flexible proposals
tailored to diverse customer needs and applications.
P10
P15
Conventional
VBM
Conventional
VHM
Latest
VLM
*For details on connectability with the P10 model, refer to the specifications of the
outdoor units.
Reduced noise level
The noise level has been reduced compared to the previous
model (PKFY-P VBM/VHM) by improving the unit structure,
including the line flow fan.
Conventional model
PKFY-P∙VLM
SPL [Lo]
Latest model
29dB
29dB
29dB
22dB
22dB
22dB
P15
P20
P25
*Measurement condition (Fan speed: Low)
*Measured in an anechoic room
Optional drain pump
The optional drain pump allows
the drain connection to be
r a i s e d a s h i g h a s 8 5 0 m m
(P10-50) or 800 mm (P63/100),
allowing more flexibility in
piping layout design.
∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167
P20
P25
P32
P40
P50
34dB
34dB
34dB
31dB
29dB
24dB
P32
P40
P50
Drain pump
Indoor unit
850 mm
(P10-50),
800 mm
(P63/100)
PKFY-P10−32VLM
Optional
Latest model
PKFY-P VLM <P10
P32>
Improved airflow control
Horizontal airflow
Airflow control has been improved to achieve horizontal airflow.
This reduces the cold draft feeling even with a wall mounted
model, while ensuring optimal air conditioning.
• Airflow distribution
PKFY-P50VLM-E <Cooling mode> Horizontal airflow
2
3.0
3.0
2.5
2.5
1
0
0
Fan speed & vane control
The VLM model provides 4 fan speeds and an auto mode.
Additionally, the vane angle can be set to five steps. This
enables air conditioning as desired.
Fan Speed
PKFY-P**
4 speeds
VBM
Conventional
3 speeds
PKFY-P**
VHM
AUTO
4 speeds
PKFY-P**
Latest
VLM-E
AUTO
PKFY-P40−50VLM
PKFY-P VKM
PKFY-P VLM <P40
P50>
[m/s]
0.5
0.5
2.0
2.0
1.5
1.5
0.5
0.5
1.0
1.0
1
2
Floor distance (m)
Vane Control
Vane Angle Swing mode
4 steps
----
+
5 steps
+
5 steps
151

Advertisement

loading

This manual is also suitable for:

S seriesWy seriesR2 seriesWr2 series