INDIVIDUAL REMOTE CONTROLLER
198
Simple Remote Controller
PAC-YT52CRA (MA)
Dimensions: 70(W) x 120(H) x 14.5(D) mm
: 2-3/4(W) x 4-3/4(H) x 19/32(D) in.
• System configuration example
Centralized controller
AE-200E
R/C: Remote controller
• Functions
Item
ON/OFF
Operation mode switching
Temperature setting
Fan speed setting
Permit / Prohibit local operation
Error
Ventilation equipment
Set temperature range limit
Dual
Dual
Set
Set
Point
Point
Simple
Simple
MA R/C
MA R/C
Changes between ON and OFF.
Select from COOL, DRY, FAN, AUTO, and HEAT.
* AUTO mode is settable only when those functions are available on the indoor unit.
Changes the set temperature.
* Set temperature range varies depending on the indoor unit model.
Changes the fan speed.
* The settable fan speed varies depending on the indoor unit model to be connected.
By setting a centralized controller, the following local operations can be prohibited: ON/OFF, operation mode,
preset temperature;
* The CENTRAL icon appears while local operations are prohibited.
Displays the current error status with the address.
* The address may not be displayed depending on the error status.
When the CITY MULTI indoor unit is connected, interlocked setting of the CITY MULTI Lossnay unit is possible.
When the Mr. SLIM indoor unit (A-control) is connected, interlocked operation of the LGH-R(V)X Type Lossnay unit is possible.
The preset temperature range can be restricted for each operation mode (COOL/HEAT/AUTO).
• Dual set point
When the operation mode is set to Auto (dual set point)
mode, two preset temperatures (one each for cooling and
heating) can be set. Depending on the room temperature, the
indoor unit will automatically operate in either the Cool or
Heat mode and keep the room temperature within the preset
range.
*Contact your Mitsubishi Electric sales office for details.
• Backlit LCD
Backlight for operation in dark places
• Flat back
The remote controller can be installed without making a hole
in the wall.
Thickness is less than 14.5 mm (19/32 in).
• Vane button (standard)
The Vane button has been added to allow users to change
airflow direction (ceiling cassette and wall mounted types).
Pressing the
button changes the vane direction.
AUTO
Setting 1
Setting 2
*The vane directions that can be set varies depending on the indoor unit
model.
* If the unit has no vane function, vane direction cannot be set.
In this case, the vane icon blinks when the
• Only cross-over wiring is required, based on two-wire
signal lines.
• Room temperature sensors are built in.
• Compatible with all types of indoor units
*As this controller has limited functions, it should always be used in
conjunction with a standard controller or centralized controller.
• LCD temperature setting and display in 1°C/1°F incre-
ments
: Each unit
Description
Setting 3
Setting 4
Setting 5
Swing
button is pressed.
: Each group
: Not available
Operations
Display
X
X