Ceiling concealed type
Fresh air intake type
Power source
Cooling capacity
Temp. range of cooling
Heating capacity
Temp. range of heating
Power consumption
*2 Cooling
*2 Heating
Current
*2 Cooling
*2 Heating
External finish
Dimension
H x W x D
Net weight
Heat exchanger
Fan
Type x Quantity
Airflow rate
External static pressure 208V
*3 220V
230V
240V
380V
400V
415V
Motor
Type
Output
Air filter (option)
Refrigerant pipe diameter
Liquid
Gas
Field drain pipe diameter
Sound pressure level
208, 220V
(measured in anechoic room) *2 *4 230, 240V
380V
400V
415V
Notes:
*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor : 33°CDB/28°CWB (91°FDB/82°FWB) Outdoor : 33°CDB (91°FDB)
Heating : Indoor : 0°CDB/-2.9°CWB (32°FDB/27°FWB) Outdoor : 0°CDB/-2.9°CWB (32°FDB/27°FWB)
Pipe length : 7.5 m (24-9/16 ft)
*2 The values are measured at the factory setting of external static pressure.
The figure of Electrical characteristic indicates at 240V 50Hz/230V 60Hz (PEFY-P80, 140VMH-E-F type), at 50Hz/60Hz (PEFY-P200, 250VMH-E-F type).
*3 The factory setting of external static pressure is shown without < >.
Refer to "Fan characteristics curves", according to the external static pressure, in DATA BOOK for the usable range of air flow rate.
*4 Measured in anechoic room with a 1 m air inlet duct and 2 m air outlet duct attached to the unit and 1.5 m below the unit.
Depending on the air conditioning load, outside temperature, and due to the activation of protection functions, the outlet air temperature may swing. Note that untreated
outside air may be delivered directly into the room upon the activation of protection functions.
The maximum connectable indoor units to 1 outdoor unit are 110% (100% in case of heating below -5°C).
When fresh air intake type indoor units connect to an outdoor unit together with other types of indoor unit, the total capacity of fresh air intake type indoor units needs to be
30% or less of the connected outdoor unit capacity.
Either a remote controller (sold separately) or a remote sensor (sold separately) must be installed to monitor the room temperature.
The AUTO mode on the local remote controller is available only when fresh air intake type indoor unit is connected to the R2 or WR2 series of outdoor unit.
The system changeover function is available only when all the connected indoor units are fresh air intake type indoor units.
The fan temporary stops during defrost.
Dry mode is not available.
In any case, the air flow rate should be kept lower than 110% of the above chart. Please see "Fan characteristics curves" in DATA BOOK for the details.
When this unit is used as sole A/C system, be careful about the dew in air outlet grilles in cooling mode.
Un-conditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation, which may occur dew condensation on the grills and ducts. Please
insulate the grills, ducts, and rooms to prevent dew condensation properly.
Air filter must be installed in the air intake side. The filter should be attached where easy maintenance in possible in case of usage of field supply filters.
PEFY-P VMH-E-F
PEFY-P80VMH-E-F
1-phase 220-240V 50Hz / 1-phase 208-230V 60Hz
*1
kW
9.0
*1
BTU/h
30,700
* Thermo-off (FAN-mode) automatically starts if the outdoor temperature is lower than 21°CD.B.
*1
kW
8.5
*1
BTU/h
29,000
* Thermo-off (FAN-mode) automatically starts if the outdoor temperature is higher than 20°CD.B.
kW
0.16 / 0.21
kW
0.16 / 0.21
A
0.67 / 0.91
A
0.67 / 0.91
380 x 1,000 x 900
mm (in.)
(15 x 39-3/8 x 35-7/16)
kg (lbs)
50 (111)
Sirocco fan x 1
3
m
/min
9.0
L/s
150
cfm
318
Pa
<35> - 85 - <170>
Pa
<40> - 115 - <190>
Pa
<50> - 130 - <210>
Pa
<80> - 170 - <220>
Pa
-
Pa
-
Pa
-
1-phase induction motor
kW
0.09 (220V, 115Pa)
Synthetic fiber unwoven cloth filter (long life)
mm (in.)
ø9.52 (ø3/8) Flare
mm (in.)
ø15.88 (ø5/8) Flare
mm (in.)
O.D.32 (1-1/4)
dB<A>
38
dB<A>
43
dB<A>
-
dB<A>
-
dB<A>
-
Level difference : 0 m (0 ft)
PEFY-P140VMH-E-F
PEFY-P200VMH-E-F
3-phase 380-415V 50Hz / 3N~ 380-415V 60Hz
16.0
22.4
54,600
76,400
21°CD.B./15.5°CW.B. ~ 43°CD.B./35°CW.B.
15.1
21.2
51,500
72,300
-10°CD.B. ~ 20°CD.B.
0.29 / 0.33
0.34 / 0.42
0.29 / 0.33
0.34 / 0.42
1.24 / 1.48
0.58 / 0.74
1.24 / 1.48
0.58 / 0.74
Galvanized
380 x 1,200 x 900
(15 x 47-1/4 x 35-7/16)
67 (148)
Cross fin (Aluminum plate fin and copper tube)
Sirocco fan x 2
18.0
28
300
467
636
989
<35> - 85 - <170>
<50> - 115 - <190>
<60> - 130 - <220>
<100> - 170 - <240>
-
<140> / 200
-
<150> / 210
-
<160> / 220
0.14 (220V, 115Pa)
0.20 (415V, 220Pa)
Synthetic fiber unwoven cloth filter (long life type)
ø19.05 (ø3/4) Brazed
38
43
-
42
-
43
-
44
SPECIFICATIONS
PEFY-P250VMH-E-F
28.0
95,500
26.5
90,400
0.39 / 0.50
0.39 / 0.50
0.68 / 0.86
0.68 / 0.86
470 x 1,250 x 1120
(18-9/16 x 49-1/4 x 44-1/8)
100 (221)
35
583
1,236
-
-
-
-
-
-
-
-
<110> / 190
<120> / 200
<130> / 210
3-phase induction motor
0.23 (415V, 210Pa)
ø9.52 (ø3/8) Brazed
ø22.2 (ø7/8) Brazed
O.D.32 (1-1/4)
-
-
-
-
44
45
46
145