Summary of Contents for Mitsubishi Electric Y Series
Page 1
VRF City Multi Product Catalogue CM20AN-E-NZ...
Page 2
Mitsubishi Electric Air Conditioning Systems Founded in 1921, Mitsubishi Electric is a globally-renowned household name with a solid reputation for excellent products and services. Since our foundation, we have risen to the very pinnacle of the air conditioning industry and we continue to maintain that position.
Contents Contents Outdoor/Heat Source Units ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.6 Outdoor/Heat Source Units ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.6 BC Controllers ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.101 BC Controllers ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.101 Indoor Units ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.112 Indoor Units ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.112 Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.162 Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.162 Ventilation Systems∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.181 Ventilation Systems∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙...
Page 4
S EL E C T IO N OUTDOOR/HEAT SOURCE UNITS/BC CONTROLLER Cooling or Heating -Series -Series -Series P.11 P.91 P.68 PUHY- PUHY- PUHY- PUMY- PUMY- PQHY- High efficiency 1-fan type 2-fan type Standard Simultaneous Cooling and Heating -Series BC CONTROLLER -Series P.12 P.69...
Page 5
SEL E C T I ON INDOOR UNITS Ceiling cassette type Ceiling concealed type PLFY- PMFY- PEFY- P.115 P.126 P.129 1-way ariflow type 4-way airflow type Low noise type 2-way ariflow type Compact depth type Low static pressure type Medium static pressure type High static pressure type Fresh air intake type Ceiling suspended type...
Source Units Mitsubishi Electric offers a wide range of products in order to meet air-conditioning needs Mitsubishi Electric offers a wide range of products in order to meet air-conditioning needs for both new constructions and existing buildings.
Page 7
• Energy-efficient with heat recovery feature • Wide range of standard and high-efficiency models up to *Data as of 1992, researched by Mitsubishi Electric Corporation 54HP *Color of the external finish depends on the production location.
Page 8
LINEUP Air cooled System Heat pump Type Y-Series Y-Series Standard High efficiency Model name PUHY-P YNW-A1(-BS) PUHY-P YSNW-A1(-BS) PUHY-EP YNW-A1(-BS) PUHY-EP YSNW-A1(-BS) Model size S size L size XL size S size L size XL modules P200 10HP P250 12HP P300 14HP P350 16HP P400 18HP P450...
Page 9
LINEUP Air cooled System Heat recovery Type R2-Series R2-Series Standard High efficiency Model name PURY-P YNW-A1(-BS) PURY-P YSNW-A1(-BS) PURY-EP YNW-A1(-BS) PURY-EP YSNW-A1(-BS) Model size S size L size XL size S size L size XL modules P200 10HP P250 12HP P300 14HP P350 16HP P400 18HP P450...
Page 10
LINEUP Water cooled Air cooled System Heat pump Heat recovery Heat pump Type S-Series S-Series WY-Series WR2-Series 1-fan type 2-fan type Model name PUMY-P VKM5(-BS) PUMY-SP VKMD-A(-BS) PQHY-P YLM-A1 PQHY-P YSLM-A1 PQRY-P YLM-A1 PQRY-P YSLM-A1 PUMY-P YKM4(-BS) PUMY-SP YKMD-A(-BS) PUMY-P YKMD-A(-BS) Model modules 3.5HP P80...
Page 11
-Series Cooling or Heating Heat pump • Features ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙P.14 - P.16 • Specifications PUHY-P Y(S)NW-A1(-BS) ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.17 - P.28 Standard PUHY-EP Y(S)NW-A1(-BS) ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.29 - P.40 High e ciency • Optional parts ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙P.41 • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙P.162 *This image shows the standard type. A two-pipe zoned system designed for heat pump operation The CITY MULTI Y-Series (for large applications) makes use of a two-pipe refrigerant system, which allows for system...
Page 12
-Series Simultaneous Cooling and Heating Heat recovery • Features ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙P.13 - P.16 PURY-P Y(S)NW-A1(-BS) • Specifications ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.42 - P.51 Standard PURY-EP Y(S)NW-A1(-BS) ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.52 - P.61 High e ciency • Optional parts ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙P.62 • BC controllers ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.101 - P.111 *This image shows the standard type.
Page 13
FUNCTIONS Benefits of the R2 system Unique to Mitsubishi Electric, our heat recovery technology uses just two pipes, as opposed to the market conventional three. Our R2 system, designed for effective simultaneous heating and cooling, offers substantial savings on installation and annual running costs.
Page 14
YNW-Series (Y/R2) The 4-face air induction structural design and core components, such as compressor and fan, realizes energy-saving performance. Energy Saving Flexible Noise Setting Various key components have been equipped, All models in the series are equipped with low-noise improving energy-saving performance and meeting operating mode as a standard feature.
Page 15
YNW-Series (Y/R2) Usable in an application with a large vertical separation of up to 90 meters Y-Series Y-Series R2-Series R2-Series Height difference from outdoor unit to indoor unit: A height difference of up to 90m from the The system can be configured with a outdoor unit to the indoor unit can be 90m with height difference of up to...
Page 16
YNW-Series (Y/R2) Compressor with centrifugal force canceling mechanism Y-Series Y-Series R2-Series R2-Series The compressor, known as the heart of the air conditioner, has been improved. A centrifugal force canceling mechanism and a multi-port mechanism have been developed. In addition, we have mounted a high-efficiency motor. The synergetic effect of these latest technologies increases the compressor performance and efficiency, and also helps to improve the performance of the outdoor unit.
Page 17
SPECIFICATIONS Y-Series Standard PUHY-P YNW-A1(-BS) Model PUHY-P200YNW-A1 (-BS) PUHY-P250YNW-A1 (-BS) PUHY-P300YNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 22.4 28.0 33.5 BTU / h 76,400 95,500 114,300...
Page 18
SPECIFICATIONS Y-Series Standard PUHY-P YNW-A1(-BS) Model PUHY-P350YNW-A1 (-BS) PUHY-P400YNW-A1 (-BS) PUHY-P450YNW-A1 (-BS) PUHY-P500YNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 40.0...
Page 19
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P400YSNW-A1 (-BS) PUHY-P450YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 45.0 50.0 BTU / h 153,500 170,600 Power input 11.62 13.15 Current input 19.6-18.6-17.9 22.1-21.0-20.3 kW / kW...
Page 20
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P500YSNW-A1 (-BS) PUHY-P550YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 56.0 63.0 BTU / h 191,100 215,000 Power input 14.97 17.54 Current input 25.2-24.0-23.1 29.6-28.1-27.1 kW / kW...
Page 21
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P600YSNW-A1 (-BS) PUHY-P650YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 69.0 73.0 BTU / h 235,400 249,100 Power input 19.88 20.79 Current input 33.5-31.8-30.7 35.0-33.3-32.1 kW / kW...
Page 22
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P700YSNW-A1 (-BS) PUHY-P750YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 80.0 85.0 BTU / h 273,000 290,000 Power input 22.47 24.56 Current input 37.9-36.0-34.7 41.4-39.3-37.9 kW / kW...
Page 23
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P800YSNW-A1 (-BS) PUHY-P850YSNW-A1 (-BS) PUHY-P900YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 90.0 96.0 101.0 BTU / h 307,100 327,600 344,600...
Page 24
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P950YSNW-A1 (-BS) PUHY-P1000YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 108.0 113.0 BTU / h 368,500 385,600 Power input 29.91 32.01 Current input 50.4-47.9-46.2 54.0-51.3-49.4 kW / kW...
Page 25
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P1050YSNW-A1 (-BS) PUHY-P1100YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 118.0 124.0 BTU / h 402,600 423,100 Power input 34.10 35.53 Current input 57.5-54.6-52.7 59.9-56.9-54.9 kW / kW...
Page 26
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P1150YSNW-A1 (-BS) PUHY-P1200YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 130.0 136.0 BTU / h 443,600 464,000 Power input 37.90 40.35 Current input 63.9-60.7-58.5 68.1-64.7-62.3 kW / kW...
Page 27
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P1250YSNW-A1 (-BS) PUHY-P1300YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 140.0 146.0 BTU / h 477,700 498,200 Power input 41.91 44.10 Current input 70.7-67.2-64.7 74.4-70.7-68.1 kW / kW...
Page 28
SPECIFICATIONS Y-Series Standard PUHY-P YSNW-A1(-BS) Model PUHY-P1350YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 150.0 BTU / h 511,800 Power input 45.73 Current input 77.1-73.3-70.6 kW / kW 3.28 Temp. range of Indoor W.B. 15.0~24.0°C (59~75°F) cooling Outdoor D.B.
Page 29
SPECIFICATIONS Y-Series High efficiency PUHY-EP YNW-A1(-BS) Model PUHY-EP200YNW-A1 (-BS) PUHY-EP250YNW-A1 (-BS) PUHY-EP300YNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 22.4 28.0 33.5 BTU / h 76,400 95,500 114,300...
Page 30
SPECIFICATIONS Y-Series High efficiency PUHY-EP YNW-A1(-BS) Model PUHY-EP350YNW-A1 (-BS) PUHY-EP400YNW-A1 (-BS) PUHY-EP450YNW-A1 (-BS) PUHY-EP500YNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 40.0...
Page 31
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP400YSNW-A1 (-BS) PUHY-EP450YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 45.0 50.0 BTU / h 153,500 170,600 Power input 10.53 12.07 Current input 17.7-16.8-16.2 20.3-19.3-18.6 kW / kW...
Page 32
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP500YSNW-A1 (-BS) PUHY-EP550YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 56.0 63.0 BTU / h 191,100 215,000 Power input 13.89 16.11 Current input 23.4-22.2-21.4 27.1-25.8-24.9 kW / kW...
Page 33
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP600YSNW-A1 (-BS) PUHY-EP650YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 69.0 73.0 BTU / h 235,400 249,100 Power input 18.11 19.46 Current input 30.5-29.0-27.9 32.8-31.2-30.0 kW / kW...
Page 34
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP700YSNW-A1 (-BS) PUHY-EP750YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 80.0 85.0 BTU / h 273,000 290,000 Power input 21.44 23.28 Current input 36.1-34.3-33.1 39.3-37.3-35.9 kW / kW...
Page 35
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP800YSNW-A1 (-BS) PUHY-EP850YSNW-A1 (-BS) PUHY-EP900YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 90.0 96.0 101.0 BTU / h 307,100 327,600 344,600...
Page 36
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP950YSNW-A1 (-BS) PUHY-EP1000YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 108.0 113.0 BTU / h 368,500 385,600 Power input 28.34 30.21 Current input 47.8-45.4-43.8 50.9-48.4-46.6 kW / kW...
Page 37
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP1050YSNW-A1 (-BS) PUHY-EP1100YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 118.0 124.0 BTU / h 402,600 423,100 Power input 32.06 33.78 Current input 54.1-51.4-49.5 57.0-54.1-52.2 kW / kW...
Page 38
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP1150YSNW-A1 (-BS) PUHY-EP1200YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 130.0 136.0 BTU / h 443,600 464,000 Power input 35.91 38.09 Current input 60.6-57.5-55.5 64.3-61.0-58.8 kW / kW...
Page 39
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP1250YSNW-A1 (-BS) PUHY-EP1300YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 140.0 146.0 BTU / h 477,700 498,200 Power input 38.99 40.55 Current input 65.8-62.5-60.2 68.4-65.0-62.6 kW / kW...
Page 40
SPECIFICATIONS Y-Series High efficiency PUHY-EP YSNW-A1(-BS) Model PUHY-EP1350YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 150.0 BTU / h 511,800 Power input 41.55 Current input 70.1-66.6-64.2 kW / kW 3.61 Temp. range of Indoor W.B. 15.0~24.0°C (59~75°F) cooling Outdoor...
Page 41
SPECIFICATIONS Optional parts • For Y-Series Description Model Remarks PAC-PH01EHY-E For S module Panel heater kit *1 PAC-PH02EHY-E For L module PAC-PH03EHY-E For XL module CMY-Y100VBK3 For PUHY-(E)P400-(E)P650YSNW-A1 Twinning kit CMY-Y200VBK2 For PUHY-(E)P700-(E)P900YSNW-A1 CMY-Y300VBK3 For PUHY-(E)P950-(E)P1350YSNW-A1 CMY-Y102SS-G2 200 or below(Total capacity of indoor unit) CMY-Y102LS-G2 201-400(Total capacity of indoor unit) Branch pipe (Joint)
Page 42
SPECIFICATIONS R2-Series Standard PURY-P YNW-A1(-BS) Model PURY-P200YNW-A1 (-BS) PURY-P250YNW-A1 (-BS) PURY-P300YNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 22.4 28.0 33.5 BTU / h 76,400 95,500 114,300...
Page 43
SPECIFICATIONS R2-Series Standard PURY-P YNW-A1(-BS) Model PURY-P350YNW-A1 (-BS) PURY-P400YNW-A1 (-BS) PURY-P450YNW-A1 (-BS) PURY-P500YNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 40.0...
Page 44
SPECIFICATIONS R2-Series Standard PURY-P YSNW-A1(-BS) Model PURY-P400YSNW-A1 (-BS) PURY-P450YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 45.0 50.0 BTU / h 153,500 170,600 Power input 11.65 13.33 Current input 19.6-18.6-18.0 22.5-21.3-20.6 kW / kW...
Page 45
SPECIFICATIONS R2-Series Standard PURY-P YSNW-A1(-BS) Model PURY-P500YSNW-A1 (-BS) PURY-P550YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 56.0 63.0 BTU / h 191,100 215,000 Power input 15.38 17.54 Current input 25.9-24.6-23.7 29.6-28.1-27.1 kW / kW...
Page 46
SPECIFICATIONS R2-Series Standard PURY-P YSNW-A1(-BS) Model PURY-P600YSNW-A1 (-BS) PURY-P650YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 69.0 73.0 BTU / h 235,400 249,100 Power input 19.43 20.50 Current input 32.8-31.1-30.0 34.6-32.8-31.6 kW / kW...
Page 47
SPECIFICATIONS R2-Series Standard PURY-P YSNW-A1(-BS) Model PURY-P700YSNW-A1 (-BS) PURY-P750YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 80.0 85.0 BTU / h 273,000 290,000 Power input 22.47 24.56 Current input 37.9-36.0-34.7 41.4-39.3-37.9 kW / kW...
Page 48
SPECIFICATIONS R2-Series Standard PURY-P YSNW-A1(-BS) Model PURY-P800YSNW-A1 (-BS) PURY-P850YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 90.0 96.0 BTU / h 307,100 327,600 Power input 26.62 29.00 Current input 44.9-42.6-41.1 48.9-46.5-44.8 kW / kW...
Page 49
SPECIFICATIONS R2-Series Standard PURY-P YSNW-A1(-BS) Model PURY-P900YSNW-A1 (-BS) PURY-P950YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 101.0 108.0 BTU / h 344,600 368,500 Power input 31.07 33.23 Current input 52.4-49.8-48.0 56.0-53.2-51.3 kW / kW...
Page 50
SPECIFICATIONS R2-Series Standard PURY-P YSNW-A1(-BS) Model PURY-P1000YSNW-A1 (-BS) PURY-P1050YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 113.0 118.0 BTU / h 385,600 402,600 Power input 33.73 39.73 Current input 56.9-54.0-52.1 67.0-63.7-61.4 kW / kW...
Page 51
SPECIFICATIONS R2-Series Standard PURY-P YSNW-A1(-BS) Model PURY-P1100YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 124.0 BTU / h 423,100 Power input 47.69 Current input 80.5-76.4-73.7 kW / kW 2.60 Temp. range of Indoor W.B. 15.0~24.0°C (59~75°F) cooling Outdoor D.B.
Page 52
SPECIFICATIONS R2-Series High efficiency PURY-EP YNW-A1(-BS) Model PURY-EP200YNW-A1 (-BS) PURY-EP250YNW-A1 (-BS) PURY-EP300YNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 22.4 28.0 33.5 BTU / h 76,400 95,500 114,300...
Page 53
SPECIFICATIONS R2-Series High efficiency PURY-EP YNW-A1(-BS) Model PURY-EP350YNW-A1 (-BS) PURY-EP400YNW-A1 (-BS) PURY-EP450YNW-A1 (-BS) PURY-EP500YNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 40.0...
Page 54
SPECIFICATIONS R2-Series High efficiency PURY-EP YSNW-A1(-BS) Model PURY-EP400YSNW-A1 (-BS) PURY-EP450YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 45.0 50.0 BTU / h 153,500 170,600 Power input 11.13 12.62 Current input 18.7-17.8-17.2 21.3-20.2-19.5 kW / kW...
Page 55
SPECIFICATIONS R2-Series High efficiency PURY-EP YSNW-A1(-BS) Model PURY-EP500YSNW-A1 (-BS) PURY-EP550YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 56.0 63.0 BTU / h 191,100 215,000 Power input 14.43 16.80 Current input 24.3-23.1-22.3 28.3-26.9-25.9 kW / kW...
Page 56
SPECIFICATIONS R2-Series High efficiency PURY-EP YSNW-A1(-BS) Model PURY-EP600YSNW-A1 (-BS) PURY-EP650YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 69.0 73.0 BTU / h 235,400 249,100 Power input 19.06 19.94 Current input 32.1-30.5-29.4 33.6-31.9-30.8 kW / kW...
Page 57
SPECIFICATIONS R2-Series High efficiency PURY-EP YSNW-A1(-BS) Model PURY-EP700YSNW-A1 (-BS) PURY-EP750YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 80.0 85.0 BTU / h 273,000 290,000 Power input 21.62 23.94 Current input 36.4-34.6-33.4 40.4-38.3-37.0 kW / kW...
Page 58
SPECIFICATIONS R2-Series High efficiency PURY-EP YSNW-A1(-BS) Model PURY-EP800YSNW-A1 (-BS) PURY-EP850YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 90.0 96.0 BTU / h 307,100 327,600 Power input 26.47 27.50 Current input 44.6-42.4-40.9 46.4-44.1-42.5 kW / kW...
Page 59
SPECIFICATIONS R2-Series High efficiency PURY-EP YSNW-A1(-BS) Model PURY-EP900YSNW-A1 (-BS) PURY-EP950YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 101.0 108.0 BTU / h 344,600 368,500 Power input 28.21 30.16 Current input 47.6-45.2-43.6 50.9-48.3-46.6 kW / kW...
Page 60
SPECIFICATIONS R2-Series High efficiency PURY-EP YSNW-A1(-BS) Model PURY-EP1000YSNW-A1 (-BS) PURY-EP1050YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 113.0 118.0 BTU / h 385,600 402,600 Power input 33.43 37.57 Current input 56.4-53.6-51.6 63.4-60.2-58.0 kW / kW...
Page 61
SPECIFICATIONS R2-Series High efficiency PURY-EP YSNW-A1(-BS) Model PURY-EP1100YSNW-A1 (-BS) Power source 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity *1,*3 124.0 BTU / h 423,100 Power input 42.75 Current input 72.1-68.5-66.0 kW / kW 2.90 Temp. range of Indoor W.B. 15.0~24.0°C (59~75°F) cooling Outdoor...
Page 62
SPECIFICATIONS Optional parts • For R2-Series Description Model Remarks PAC-PH01EHY-E For S module Panel heater kit *1 PAC-PH02EHY-E For L module PAC-PH03EHY-E For XL module CMY-R100VBK4 For PURY-(E)P400-(E)P650YSNW-A1 Twinning kit CMY-R200VBK4 For PURY-(E)P700-(E)P1100YSNW-A1 CMY-Y102SS-G2 200 or below(Total capacity of indoor unit) 2-Branch Joint Pipe CMY-Y102LS-G2 201-400(Total capacity of indoor unit)
Page 63
Zubadan Heating or Cooling PUHY-HP YHM-A(-BS) ZUBADAN series PUHY-HP YSHM-A(-BS) Bringing year round comfort solutions to extreme climates CITY MULTI ZUBADAN series combines the ultimate in application flexibility and powerful cooling and heating capabilities to deliver precise comfort even in the coldest days of the year down to -25°C. The technology behind this is a Flash Injection Circuit which provides the optimum amount of refrigerant to the system via a compressor through a specially designed injection port to ensure a particularly stable operation.
Page 64
ZUBADAN Stable Heating Performance Even at -15°C (kW) PUHY-HP400 YSHM-A 50.0 Using an industry first ‘Flash-injection Full heating capacity even Circuit’, the ZUBADAN System is able -15°C to provide FULL heating performance in PUHY-HP250 YHM-A ambient temperatures as low as -15°C. 25.0 Capacity improvement by...
Page 65
ZUBADAN ZUBADAN High Static Pressure Setting With our new ZUBADAN model, high static pressure setting up to 60Pa is available by setting the dip switch (0Pa at factory setting) making it an ideal and flexible solution for any type of application. Shorter Warm-up in About 20 Minutes.
Page 66
ZUBADAN ZUBADAN Maximum Stable Operation By utilising our advanced Flash Injection Circuit, the system can not only provide continuous heating for up to 250 minutes Heating up to Reduced in one continuous cycle, but also significantly lessens defrost 250 min. straight Defrosting time time to give exceptionally stable heating operation.
Page 67
ZUBADAN OUTDOOR UNIT ZUBADAN (Heat Pump) Series(Y) PUHY-HP Y(S)HM-A(-BS) Specifications Set name PUHY-HP200YHM-A(-BS) PUHY-HP250YHM-A(-BS) PUHY-HP400YSHM-A(-BS) PUHY-HP500YSHM-A(-BS) Power source 3-phase 4-wire 380-400-415V 50/60Hz 22.4 28.0 Cooling capacity 45.0 56.0 (Nominal) BTU/h 76,400 95,500 153,500 191,100 6.40 9.06 Power input 12.86 18.16 Current input 10.8-10.2-9.8 15.2-14.5-14.0...
Page 68
-Series Cooling or Heating Heat pump • Features ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.70, P.72 - P.73 • Specifications PQHY-P Y(S)LM-A1∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.74 - P.80 • Optional parts ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.81 • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙P.162 Dual A water energy source system that allows switching between cooling and heating The CITY MULTI WY-Series provides all the benefits of the Y-Series using water-cooled heat source units.
Page 69
-Series Simultaneous Cooling and Heating Heat recovery • Features ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.70 - P.73 • Specifications PQRY-P Y(S)LM-A1∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.82 - P.89 • Optional parts ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.90 • BC controllers ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.101 - P.111 • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙P.162 Dual Advanced water heat source unit with the benefits of the R2-Series The CITY MULTI WR2-Series provides all of the advantages of the R2-Series with the added benefits of a water heat source system, making it suitable for a wider range of applications in high-rise buildings, cold climates, coastal areas,...
Page 70
Benefits of the WY/WR2-Series What is Water-Cooled? A unique system from Mitsubishi Electric It is possible now to combine the features of VRF with a water circuit using CITY MULTI WR2/WY. In this case, the heat is discharged to a water source rather than to the outside air.
Page 71
Benefits of the WR2-Series Double heat recovery (WR2-Series) Mitsubishi Electric now offers double heat recovery operation. The first heat recovery is within the refrigerant system. Heat is recovered between the indoor units to allow simultaneous cooling and heating operation. The second heat recovery is within the water loop, where heat is recovered between the PQRY units.
Page 72
YLM-Series (WY/WR2) A wide range of capacities are available, from single modules capable of up to P600 and combination modules up to P900. Single or combination module units are available to meet various installation conditions and capacity requirements. Y(S)HM-A Y(S)LM-A1 mm (in.) mm (in.) module...
Page 73
YLM-Series (WY/WR2) High energy efficiency High EER and COP compared to conventional models • Comparison of single module P300 units • Comparison of combination module P600 units PQHY-P300YLM-A1 PQHY-P600YSLM-A1 PQHY-P300YHM-A PQHY-P600YSHM-A 6.00 6.00 5.54 5.37 4.55 4.60 4.45 4.46 Water flow rate control System energy consumption can be improved by changing the water Command to adjust valve opening flow volume during partial load and thereby reducing water pump...
Page 74
SPECIFICATIONS WY-Series PQHY-P YLM-A1 Model PQHY-P200YLM-A1 PQHY-P250YLM-A1 PQHY-P300YLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 22.4 28.0 33.5 (Nominal) kcal / h 20,000 25,000 30,000 *1 BTU / h 76,400 95,500...
Page 75
SPECIFICATIONS WY-Series PQHY-P YLM-A1 Model PQHY-P350YLM-A1 PQHY-P400YLM-A1 PQHY-P450YLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 40.0 45.0 50.0 (Nominal) kcal / h 35,000 40,000 45,000 *1 BTU / h 136,500 153,500...
Page 76
SPECIFICATIONS WY-Series PQHY-P YLM-A1 Model PQHY-P500YLM-A1 PQHY-P550YLM-A1 PQHY-P600YLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 56.0 63.0 69.0 (Nominal) kcal / h 50,000 55,000 60,000 *1 BTU / h 191,100 215,000...
Page 77
SPECIFICATIONS WY-Series PQHY-P YSLM-A1 Model PQHY-P400YSLM-A1 PQHY-P450YSLM-A1 PQHY-P500YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 45.0 50.0 56.0 (Nominal) kcal / h 40,000 45,000 50,000 *1 BTU / h 153,500 170,600...
Page 78
SPECIFICATIONS WY-Series PQHY-P YSLM-A1 Model PQHY-P550YSLM-A1 PQHY-P600YSLM-A1 PQHY-P700YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 63.0 69.0 80.0 (Nominal) kcal / h 55,000 60,000 68,800 *1 BTU / h 215,000 235,400...
Page 79
SPECIFICATIONS WY-Series PQHY-P YSLM-A1 Model PQHY-P750YSLM-A1 PQHY-P800YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 85.0 90.0 (Nominal) kcal / h 73,100 77,400 *1 BTU / h 290,000 307,100 Power input 15.64 16.57 Current input 26.4-25.0-24.1...
Page 80
SPECIFICATIONS WY-Series PQHY-P YSLM-A1 Model PQHY-P850YSLM-A1 PQHY-P900YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 96.0 101.0 (Nominal) kcal / h 82,600 86,900 *1 BTU / h 327,600 344,600 Power input 18.03 19.38 Current input 30.4-28.9-27.8...
Page 81
SPECIFICATIONS Optional parts • For PQHY-Series Description Model Remarks CMY-Y102SS-G2 200 or below (Total capacity of indoor unit) CMY-Y102LS-G2 201~400 (Total capacity of indoor unit) Branch pipe (Joint) 401~650 (Total capacity of indoor unit) CMY-Y202S-G2 The first branch of P450-P650 CMY-Y302S-G2 651 or above (Total capacity of indoor unit) CMY-Y104-G...
Page 82
SPECIFICATIONS WR2-Series PQRY-P YLM-A1 Model PQRY-P200YLM-A1 PQRY-P250YLM-A1 PQRY-P300YLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 22.4 28.0 33.5 (Nominal) kcal / h 20,000 25,000 30,000 *1 BTU / h 76,400 95,500...
Page 83
SPECIFICATIONS WR2-Series PQRY-P YLM-A1 Model PQRY-P350YLM-A1 PQRY-P400YLM-A1 PQRY-P450YLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 40.0 45.0 50.0 (Nominal) kcal / h 35,000 40,000 45,000 *1 BTU / h 136,500 153,500...
Page 84
SPECIFICATIONS WR2-Series PQRY-P YLM-A1 Model PQRY-P500YLM-A1 PQRY-P550YLM-A1 PQRY-P600YLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 56.0 63.0 69.0 (Nominal) kcal / h 50,000 55,000 60,000 *1 BTU / h 191,100 215,000...
Page 85
SPECIFICATIONS WR2-Series PQRY-P YSLM-A1 Model PQRY-P400YSLM-A1 PQRY-P450YSLM-A1 PQRY-P500YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 45.0 50.0 56.0 (Nominal) kcal / h 40,000 45,000 50,000 *1 BTU / h 153,500 170,600...
Page 86
SPECIFICATIONS WR2-Series PQRY-P YSLM-A1 Model PQRY-P550YSLM-A1 PQRY-P600YSLM-A1 PQRY-P700YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 63.0 69.0 80.0 (Nominal) kcal / h 55,000 60,000 68,800 *1 BTU / h 215,000 235,400...
Page 87
SPECIFICATIONS WR2-Series PQRY-P YSLM-A1 Model PQRY-P750YSLM-A1 PQRY-P800YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 85.0 90.0 (Nominal) kcal / h 73,100 77,400 *1 BTU / h 290,000 307,100 Power input 15.64 16.57 Current input 26.4-25.0-24.1...
Page 88
SPECIFICATIONS WR2-Series PQRY-P YSLM-A1 Model PQRY-P850YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 96.0 (Nominal) kcal / h 82,600 *1 BTU / h 327,600 Power input 18.03 Current input 30.4-28.9-27.8 kW / kW 5.32 Temp. range of Indoor W.B.
Page 89
SPECIFICATIONS WR2-Series PQRY-P YSLM-A1 Model PQRY-P900YSLM-A1 Power source 3-phase 4-wire 380-400-415 V 50/60 Hz Cooling capacity 101.0 (Nominal) kcal / h 86,900 *1 BTU / h 344,600 Power input 19.38 Current input 32.7-31.0-29.9 kW / kW 5.21 Temp. range of Indoor W.B.
Page 90
SPECIFICATIONS Optional parts • For PQRY-Series Description Model Remarks CMY-Y102SS-G2 200 or below (Total capacity of indoor unit) Branch pipe (Joint) CMY-Y102LS-G2 201~400 (Total capacity of indoor unit) CMY-Q100CBK2 For PQRY-P400~P600YSLM-A1 Twinning kit CMY-Q200CBK For PQRY-P700~P900YSLM-A1 CMY-Y102SS-G2 200 or below(Total capacity of indoor unit) 2-Branch Joint Pipe CMY-Y102LS-G2 201-400(Total capacity of indoor unit)
Page 91
-Series Cooling or Heating Heat pump • Features ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.92 - P.96 • Optional parts ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.94 • Specifications PUMY-SP VKMD-A (-BS)/YKMD-A (-BS)∙∙∙∙∙∙∙∙ P.97 - P.98 1-fan type PUMY-P VKM5 (-BS)/YKM4 (-BS)/YKMD-A (-BS)∙∙∙∙∙∙∙ P.99 - P.100 2-fan type Cooling/heating changeover system with horizontal airflow for small offices and stores The CITY MULTI S-Series (for small applications) makes use of a two-pipe refrigerant system, which allows for system changeover from cooling to heating, ensuring that a constant indoor climate is maintained in all zones.
Page 92
VKM/YKM-Series Lineup of the VKM/YKM-Series A compact single-fan unit is available to better suit individual installation conditions. PUMY-SP80, 112, 125, 140VKMD-A/ PUMY-P112, 125, 140VKM5/YKM4 (-BS) 1-fan type 2-fan type YKMD-A (-BS) PUMY-P200YKMD-A (-BS) VKMD model…Single-phase type VKM model…Single-phase type YKMD model…Three-phase type YKM, YKMD model…Three-phase type Unit: mm [in.] Unit: mm [in.]...
Page 93
VKM/YKM-Series Flexible noise setting The 2-fan models have a quiet noise mode, and the 1-fan models have two super quiet modes in addition to the general quiet mode, so a suitable noise level can be selected. The pattern can be selected according to customer needs for low-noise operation.
Page 94
VKM/YKM-Series Rear piping is possible 1-fan type 2-fan type • Flexible 4 way layout for easier connection The indoor unit allows piping from any of four directions: front, back, bottom, or right. This enables easier Back horizontal connection for collective layouts. The outdoor unit also allows expanded piping layout flexibility to greatly improve piping workability.
Page 95
Using a branch box with a PUMY-Series device makes it possible to connect not only to CITY MULTI indoor units but also to Mitsubishi Electric indoor units that do not normally support M-NET connections. Thus it is possible to connect to room air conditioners and Mr. SLIM indoor units, allowing for a selection specifically designed to suit how the room is being used.
Page 96
VKM/YKM-Series Precautions for system design • The capacity and number of indoor units when using a branch box differs from situations when no branch box is used. Refer to the installation manual for each outdoor unit for more information. Moreover, the indoor unit lineup varies from country to country, so contact your local distributor for details.
Page 102
For R2/WR2-Series (R2) The secret of CITY MULTI heat recovery systems lies in the BC Controller The BC controller houses a liquid/gas separator, allowing the outdoor/heat source unit to deliver a mixture (2-phase) of hot gas for heating and liquid for cooling, all through the same pipe.
Page 103
NEW BC CONTROLLER Lineup Conventional model Latest model Type Model name Type Model name Usage Main BC controller CMB-P**V-J CMB-M**V-J1 Main BC controller CMB-P**V-JA CMB-M**V-JA1 with sub BC controller Main BC controller CMB-P**V-KA CMB-P**V-KA1 with sub BC controller CMB-P**V-KB CMB-M**V-KB1 Sub BC controller *When mixing the use of a conventional (J/JA/KA/KB type) and latest (J1/JA1/KA1/KB1 type) BC controller, please refer to the DATABOOK for details.
Page 104
BC CONTROLLER • System with multiple BC controllers Main BC controller Sub BC controller (JA1 or KA1 type) (KB1 type) Heat source unit Outdoor unit Main BC controller used with sub BC controller (JA1 and KA1 types) Model CMB-M108V-JA1 CMB-M1012V-JA1 CMB-M1016V-JA1 CMB-P1016V-KA1 Number of branches...
Page 105
BC CONTROLLER Optional parts • For BC controllers Branch pipe (Header) CMY-R160-J1 Joint for connecting to two nozzles...
Page 106
SPECIFICATIONS CMB-M V-J1 CMB-M V-JA1 CMB-P V-KA1 CMB-M V-KB1 CMB-M V-J1 CMB-M V-JA1 CMB-M V-KB1 CMB-M V-KB1 CMB-P V-KA1 CMB-M V-KB1 CMB-M V-KB1 J1 type CMB-M V-J1 Model CMB-M104V-J1 CMB-M106V-J1 CMB-M108V-J1 Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz 50 Hz 60 Hz...
Page 107
SPECIFICATIONS J1 type CMB-M V-J1 Model CMB-M1012V-J1 CMB-M1016V-J1 Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz 50 Hz 60 Hz Cooling 0.186/0.211/0.236 0.150/0.168/0.186 0.246/0.279/0.312 0.198/0.222/0.246 Power input (220/230/240) Heating 0.090/0.102/0.114 0.072/0.081/0.090 0.119/0.135/0.151 0.096/0.108/0.119 Cooling 0.85/0.92/0.99 0.69/0.74/0.78 1.12/1.22/1.30 0.90/0.97/1.03 Current input...
Page 108
SPECIFICATIONS JA1 type CMB-M V-JA1 Model CMB-M108V-JA1 CMB-M1012V-JA1 Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz 50 Hz 60 Hz Cooling 0.127/0.144/0.161 0.102/0.115/0.127 0.186/0.211/0.236 0.150/0.168/0.186 Power input (220/230/240) Heating 0.060/0.068/0.076 0.048/0.054/0.060 0.090/0.102/0.114 0.072/0.081/0.090 Cooling 0.58/0.63/0.68 0.47/0.50/0.53 0.85/0.92/0.99 0.69/0.74/0.78 Current input...
Page 109
SPECIFICATIONS JA1 type CMB-M V-JA1 Model CMB-M1016V-JA1 Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz Cooling 0.246/0.279/0.312 0.198/0.222/0.246 Power input (220/230/240) Heating 0.119/0.135/0.151 0.096/0.108/0.119 Cooling 1.12/1.22/1.30 0.90/0.97/1.03 Current input (220/230/240) Heating 0.55/0.59/0.63 0.44/0.47/0.50 External finish Galvanized steel plate (Lower part drain pan: Pre-coated galvanized sheets + powder coating) Connectable outdoor/heat source unit capacity P200 to P900 Indoor unit capacity...
Page 110
SPECIFICATIONS KA1 type CMB-P V-KA1 Model CMB-P1016V-KA1 Number of branch Power source 1-phase 220-230-240 V 50Hz 60Hz Cooling 0.246/0.279/0.312 0.198/0.222/0.246 Power input (220/230/240) Heating 0.119/0.135/0.151 0.096/0.108/0.119 Cooling 1.12/1.22/1.30 0.90/0.97/1.03 Current input (220/230/240) Heating 0.55/0.59/0.63 0.44/0.47/0.50 External finish Galvanized steel plate (Lower part drain pan: Pre-coated galvanized sheets + powder coating) Connectable outdoor/heat source unit capacity P200 to P1100 Indoor unit capacity...
Page 111
SPECIFICATIONS KB1 type CMB-M V-KB1 Model CMB-M104V-KB1 CMB-M108V-KB1 Number of branch Power source 1-phase 220-230-240 V 50 Hz 60 Hz 50 Hz 60 Hz Cooling 0.060/0.068/0.076 0.048/0.054/0.060 0.119/0.135/0.151 0.096/0.108/0.119 Power input (220/230/240) Heating 0.030/0.034/0.038 0.024/0.027/0.030 0.060/0.068/0.076 0.048/0.054/0.060 Cooling 0.28/0.30/0.32 0.22/0.24/0.25 0.55/0.59/0.63 0.44/0.47/0.50 Current input...
Page 113
LINEUP Wide Selection of Indoor Units Ceiling cassette type Ceiling concealed type Type 4-way airfl ow type 4-way airfl ow type 2-way airfl ow type 1-way airfl ow type Low noise type Compact depth type PLFY-P VEM-E/A PLFY-P VFM-E1 PLFY-P VLMD-E PMFY-P VBM-E PEFY-P VMR-E-L/R PEFY-P VMX(L)-E(1) Model ●...
Page 114
eiling Cassette Type 4-Way Airflow Type...
Page 115
Ceiling cassette type 4-way airflow type PLFY-P VEM-E/A • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 Optional Optional 3D i-see Sensor and versatile airflow variation provide comfort to all corners of the room. Optimum airflow 2-, 3-, 4-way airflow pattern Individual vane angle Multi-directional selection settings...
Page 116
Horizontal airflow Supply air is horizontally fed into the room to reduce the cold draft feeling. This airflow is ideal for offices and restaurants. <Cooling mode> Standard • Airflow distribution • Horizontal airflow Flow angle: 10° 4-way flow PLFY-P80VEM-A Ceiling height: 2.7m (m/s) Cold air doesn’t affect...
Page 117
SPECIFICATIONS Ceiling cassette type 4-way airfl ow type PLFY-P VEM-E/A PLFY-P20VEM-E PLFY-P25VEM-E Power source 1-phase 220–240V 50Hz, 1-phase 220V 60Hz Cooling capacity (Nominal) BTU/h 7,500 9,600 Power input 0.03 0.03 Current input 0.31 0.31 Heating capacity (Nominal) BTU/h 8,500 10,900 Power input 0.03 0.03...
Page 118
SPECIFICATIONS Optional parts • For PLFY-P VEM-E/A Description Model Applicable capacity Air outlet shutter plate PAC-SJ37SP-E P20, P25, P32, P40, P50, P63, P80, P100, P125 Multi-function casement PAC-SJ41TM-E P20, P25, P32, P40, P50, P63, P80, P100, P125 High effi ciency fi lter element PAC-SH59KF-E P20, P25, P32, P40, P50, P63, P80, P100, P125 Space panel...
Page 119
eiling Cassette Type 4-Way Airflow Type – Compact...
Ceiling cassette type 4-way airflow type PLFY-P VFM-E1 • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 Optional The compact size offers a perfect fit to grid system ceilings (600 mm × 600 mm) and provides 4-way airflows despite its size. Beautiful square design The square design matches 2 ×...
Page 122
eiling Cassette Type 2-Way Airflow Type...
Page 123
Ceiling cassette type 2-way airflow type PLFY-P VLMD-E • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 Slim body (depth 634 mm) for up to P 1 00. Recommended for corridors or long and narrow rooms. Simple panel design The unobtrusive slim-line profile of the cassette is designed to work in harmony with ceilings and light fittings especially in narrow long areas.
Page 125
eiling Cassette Type 1-Way Airflow Type...
Page 126
Ceiling cassette type 1-way airflow type PMFY-P VBM-E • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 Recommended for installation at the edges of a room. A lightweight body ensures excellent workability. Ceiling mounted installation Installing a 1-way airflow type unit in a room creates a more spacious feel No access that enhances room comfort.
Page 129
Low noise type Compact depth type PEFY-P VMR-E-L/R PEFY-P VMX(L)-E(1) P.130 P.132 • Realizes low noise operation. Most suitable for places such • Measures only 450 mm* in depth and 200 mm in height. as hotels where low noise operation is required. Installable in a limited space such as in a room with a clipped ceiling.
Page 130
Ceiling concealed type Low noise type PEFY-P VMR-E-L/R • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 *This image shows the -L type. On the -R type, the control box comes to the right side when looked at from the front. Realizes low noise operation as well as reduced construction work and maintenance, to create a comfortable room environment.
Page 132
Ceiling Ceiling Ceiling For VMX, Mitsubishi Electric has developed a unique technique of simultaneous return air Outlet intake from the top and rear side of an indoor unit. Filter and switches are accessible from the bottom for easy maintenance and setting change.
Page 133
SPECIFICATIONS Ceiling concealed type Compact depth type PEFY-P VMX(L)-E(1) PEFY-P15VMX-E (1) PEFY-P20VMX-E (1) PEFY-P25VMX-E (1) PEFY-P32VMX-E (1) PEFY-P40VMX-E (1) PEFY-P50VMX-E (1) PEFY-P63VMX-E (1) Power source 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-240 V 50/60 Hz 1-phase 220-230-240 V 50/60 Hz Cooling capacity (Nominal) BTU/h...
Page 134
Ceiling concealed type Low static pressure type PEFY-P VMS1(L)-E • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 VMS1 VMS1L Optional *This image shows the VMS1 type (equipped with a drain pump as a standard feature). A thin body 200 mm in height and a maximum external static pressure rating of 50 Pa provides significant flexibility of design and allows installation in narrow ceiling spaces.
Page 136
Ceiling concealed type Medium static pressure type PEFY-P VMA(L)-E • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 *This image shows the VMA type (equipped with a drain pump as a standard feature). A wide range of external static pressure and the slim 250mm-height body provide design flexibility for narrow ceiling spaces.
Page 139
Ceiling concealed type High static pressure type PEFY-P VMHS-E PEFY-P VMHS-E (P40-P140) • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 Optional PEFY-P VMHS-E (P200/P250) A wide range of external static pressure options to match A wide range of external static pressure options to match virtually any application.
Page 140
P 1 40 (6 HP) and smaller models with a DC motor The use of a DC motor In the past, the only models featuring a DC motor were the P200 (8 HP) and P250 (10 HP). Now, the P140 (6 HP) and smaller models feature a DC motor that consumes less power compared to AC motors.
Page 141
SPECIFICATIONS Ceiling concealed type High static pressure type PEFY-P VMHS-E PEFY-P40VMHS-E PEFY-P50VMHS-E PEFY-P63VMHS-E PEFY-P71VMHS-E PEFY-P80VMHS-E Power source 1-phase 220-230-240 V 50/60 Hz Cooling capacity (Nominal) *1 BTU/h 15,400 19,100 24,200 27,300 30,700 *2 Power input 0.055 0.055 0.090 0.075 0.090 *2 Current input 0.41 - 0.39 - 0.38 0.41 - 0.39 - 0.38...
Page 142
SPECIFICATIONS Ceiling concealed type High static pressure type PEFY-P VMHS-E PEFY-P100VMHS-E PEFY-P125VMHS-E PEFY-P140VMHS-E PEFY-P200VMHS-E PEFY-P250VMHS-E Power source 1-phase 220-230-240 V 50/60 Hz 1-phase 220-240V 50Hz / 1-phase 220-240V 60Hz Cooling capacity 11.2 14.0 16.0 22.4 28.0 (Nominal) *1 BTU/h 38,200 47,800 54,600 76,400...
Page 148
Ceiling suspended type PCFY-P VKM-E • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 Optional Optional A stylish indoor unit design and optional drain pump expand installation possibilities. Easy installation Drain pumps can be supported throughout the horsepower range. (Optional) The ceiling suspended cassette can easily be installed without requiring ductwork, even if the ceiling does not have sufficient The optional drain pump allows the drain connection to be raised space.
Page 151
Wall-mounted type PKFY-P VLM-E PKFY-P10−32VLM PKFY-P40−50VLM PKFY-P VKM-E • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 PKFY-P VKM Optional Sophisticated design matches any interior. A design that matches any room interior (VLM model) A sharp and simple form combines beauty and function. The simple square design harmonizes beautifully with the straight lines of the walls, floor and ceiling.
Page 155
Easy, regular cleaning helps to maintain energy-efficient operation. Quiet operation (lowest noise level among most floor standing types) • Noise level Mitsubishi Electric air conditioners have always been some *2.5kw class ONLY of the quietest models available in the market. The new...
Page 157
Floor standing type Exposed type PFFY-P VLEM-E • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 This floor standing type allows efficient air conditioning around the perimeter of a room. It adopts a low-height design that does not block the daylight from the windows. Compact unit for perimeter Remote controller storage in air conditioning...
Page 159
Floor standing type Concealed type PFFY-P VLRM-E PFFY-P VLRMM-E • Technologies and functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167 VLRMM VLRMM Fits neatly and easily installed in perimeter zone. Concealed design ensures harmony with Compact unit for easy perimeter air any interior conditioning The compact body is only 220 mm (8-11/16 in.) in depth, so it can The embedded type design makes it possible to install the unit be easily installed and concealed in a perimeter counter.
Page 162
Y-Series R2-Series WR2-Series Power modules manufactured by Mitsubishi Electric are installed in the compressor, which is the core component, as well as in the inverter circuit board that drives the fan. SiC (silicon carbide) is used in the power module that is equipped with a voltage-boosting circuit to raise the output voltage of the inverter and expand the operating range.
Page 163
TECHNOLOGY INTRODUCTION PWM control Y-Series R2-Series WY-Series Y-Series R2-Series WR2-Series PWM control is used to control the number of motor revolutions according to operational load. It varies the inverter pulse width (electric signal wave occurring over a short period) to control the output.
Page 164
TECHNOLOGY INTRODUCTION Heat Inter-Changer (HIC) circuit Y-Series R2-Series WY-Series Y-Series R2-Series WR2-Series The HIC circuit increases cooling efficiency. This technology raises the degree of supercooling, increasing both cooling capacity and cooling efficiency. The HIC circuit is installed before the point at which the high pressure liquid refrigerant, which passes through the heat exchanger of the outdoor/heat source unit, flows into the indoor unit.
Page 165
OUTDOOR/HEAT SOURCE UNIT FUNCTION TABLE IH warmer Y-Series R2-Series WY-Series Y-Series R2-Series WR2-Series Induction heating (IH) is used to heat the refrigerant that flows back into the compressor*. This method differs from the conventional crankcase heater method (in which a belt heater is wrapped around the outside of the compressor) in that heat is not applied from the outside;...
Page 166
TECHNOLOGY INTRODUCTION Mitsubishi Electric’s outdoor units and heat source units utilize the latest technology and off er a wide variety of functions. See the preceding pages for details of each technology and function. : Available −: Not available Air cooled...
Page 167
VRF INDOOR UNIT FUNCTION TABLE : Standard : Optional −: Not available Ceiling cassette type Ceiling concealed type Type 2-way 1-way Low noise Compact Low static Medium static 4-way airfl ow type airfl ow type airfl ow type type depth type pressure type pressure type PLFY-P...
Page 168
VRF INDOOR UNIT FUNCTION TABLE : Standard : Optional −: Not available Ceiling concealed type Floor standing type Ceiling suspended Wall mounted type High static Concealed type Fresh air intake type Exposed type pressure type type PEFY-P PEFY-P PEFY-P PCFY-P PKFY-P PKFY-P PFFY-P...
Page 169
OUTDOOR UNIT FUNCTIONS Operation mode COP priority mode Y-Series R2-Series Y-Series R2-Series The operation pattern under low ambient temperature conditions can be selected and the priority mode setting (“Capacity priority mode” and “COP priority mode”) can be switched with the function settings. Each mode is activated when the ambient temperature is below the specified temperature.
Page 170
OUTDOOR UNIT FUNCTIONS System changeover (for heat pumps) Y-Series Y-Series WY-Series Normal switching between cooling and heating Using system changeover to switch between cool- ing and heating With CITY MULTI's switchable cooling/heating models, in Depending on the dip switch settings, the operation mode of all order to switch from cooling to heating, the operation indoor units can be automatically switched according to the mode of all indoor units performing cooling operation...
Page 171
OUTDOOR UNIT FUNCTIONS Dual set point Y-Series R2-Series WY-Series Y-Series R2-Series WR2-Series Normally, the desired room temperature is set to the same value for cooling and heating. However, the dual set point function allows different temperatures to be set for cooling and heating. When operation switches from cooling to heating or vice versa, the preset temperature changes accordingly.
Page 172
OUTDOOR UNIT FUNCTIONS Energy efficiency control Evaporating temperature control (during cooling) Y-Series R2-Series WY-Series Y-Series R2-Series WR2-Series During cooling, the temperature of the refrigerant is controlled according to the air conditioning load. This helps to ensure energy-efficient operation. Normal mode Smart evaporating temperature control mode The evaporating temperature is The evaporating temperature is increased and the compressor input is decreased...
Page 173
OUTDOOR UNIT FUNCTIONS High sensible heat operation (during cooling) Y-Series R2-Series WY-Series Y-Series R2-Series WR2-Series Evaporating temperature is controlled according to room temperature and humidity. • Image of evaporating temperature control during high sensible heat operation in full cooling mode In high sensible heat operation mode, air conditioners consume less energy, thereby realizing cost savings.
Page 174
OUTDOOR UNIT FUNCTIONS Demand control Y-Series R2-Series WY-Series Y-Series R2-Series WR2-Series This function reduces the capacity of the outdoor/heat source unit by way of the external input to the outdoor unit. The capacity of the outdoor unit can be reduced in steps, with patterns ranging from 2 to 12 control steps depending on the system.
Page 175
OUTDOOR UNIT FUNCTIONS Selectable external static pressure of the outdoor unit Y-Series Y-Series R2-Series R2-Series The static pressure specification for the outdoor unit can be selected (0, 30, 60, or 80 Pa). This facilitates installation of the unit on each floor of a high-rise building or on balconies. * The static pressure that can be set varies depending on the model.
Page 176
OUTDOOR UNIT FUNCTIONS Maintenance functions Rotation control Alternate Y-Series R2-Series WY-Series operation Y-Series R2-Series WR2-Series With the combination model, the outdoor/heat source units operate alternately. This reduces operating load and leads to a longer service life. Emergency operation mode Rest assured in case of unit failure Y-Series R2-Series...
Page 177
INDOOR UNIT FUNCTIONS i-see Sensor PLFY PLFY Optional Optional 360° 360° • Highly accurate people detection Detects people’s positions detection detection and number of people A total of eight sensors fully rotate 360° in 2.7m Detects floor 3-minute intervals. In addition to temperature 7.2m detecting human body temperature,...
Page 178
INDOOR UNIT FUNCTIONS Air distribution Automatic air-speed adjustment PLFY PLFY PEFY PEFY PEFY PEFY PCFY PKFY PFFY PFFY *1. VLRMM only An automatic Air-speed mode automatically adjusts airflow speed to maintain comfortable room conditions at all times. This setting automatically adjusts the air speed to conditions that match the room environment. At the start of the When the room temperature heating/cooling operation,...
Page 179
INDOOR UNIT FUNCTIONS Convenience Dry operation PLFY PLFY PLFY PMFY PEFY PEFY PEFY PEFY PEFY PCFY PKFY PKFY PFFY PFFY PFFY PFFY The Dry mode is a dehumidifying mode in which the unit intermittently operates in a mild cooling mode. During seasons when operating the unit in the Cooling mode tends to overcool the room, such as during the rainy season, the Dry mode helps keep the room at a comfortable temperature by reducing the room temperature by a few degrees centigrade.
Page 180
INDOOR UNIT FUNCTIONS Installability and serviceability Drain pump PLFY PLFY PLFY PMFY PEFY PEFY PEFY PEFY PEFY MHS-F PEFY MH-F PCFY PKFY PKFY Optional Optional Optional Optional Optional Optional *1. VMX only *2. Optional for PEFY-P-VMS1L-E and PEFY-W-VMS-A *3. VMA only Built-in drain pump A built-in drain pump (optional for some models) (optional for some models)
Page 182
• Lossnay lineup Airflow 1000 1500 2000 2500 Unit type Model LGH-RVX Series Lossnay Unit LGH-RVXT Series GUF Series LGH-RVX Series LGH-RVXT Series GUF Series A commercially oriented system that Thin, large airflow models of the Heat recovery units with a heating and can be used to deliver high performance LGH Series that deliver high cooling system that uses the CITY...
Page 183
LGH-RVX/RVXT Series / GUF Series Lossnay ventilation systems are renowned industry-wide for their efficiency. They offer environmentally friendly energy recovery and humidity control, and enable air-conditioning systems to simultaneously provide optimum room comfort and energy savings. Indoor Air Quality Inside a Building is Optimized Through Temperature and Humidity Exchange by Lossnay Lossnay is a total heat exchange ventilation system that uses paper characteristics to perform temperature (sensible heat) and humidity...
Page 184
INTRODUCTION LGH-RVX Series (Standard model) • Further reduction of power consumption Comparison between latest and conventional power consumption (Latest model: Fan speed 4 at 230V 50Hz, Conventional model: Extra-high at 220V 50Hz) with the introduction of a DC motor Low power consumption is realized with the introduction of a high efficiency brushless DC motor.
Page 185
CHARACTERISTIC CURVES • LGH-RVX Series LGH-15RVX-E LGH-25RVX-E LGH-35RVX-E Model Electrical power supply 220-240V/50Hz, 220V/60Hz 220-240V/50Hz, 220V/60Hz 220-240V/50Hz, 220V/60Hz Ventilation mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode Heat recovery mode Bypass mode Fan speed Running current (A) 0.40 0.24 0.15...
Page 186
SPECIFICATIONS LGH-15RVX-E LGH-25RVX-E LGH-35RVX-E 150mm dia straight pipe length 150mm dia straight pipe length 100mm dia straight pipe length (L/s) (L/s) (L/s) Airflow Airflow Airflow LGH-50RVX-E LGH-65RVX-E LGH-80RVX-E 200mm dia straight pipe length 200mm dia straight pipe length 250mm dia straight pipe length 100m 1000 1200...
Page 187
FILTERS Filters • Standard filters Filter Lossnay Classification Filter Included Required Model name Applicable model material piece/set filter pieces ISO 16890 EN779 (2012) LGH-15RVX-E PZ-15RF PZ-25RF LGH-25RVX-E PZ-35RF LGH-35RVX-E PZ-50RF LGH-50RVX-E, GUF-50RD4 Coarse 35% G3 * PZ-65RF LGH-65RVX-E Non-woven LGH-80RVX-E fabrics PZ-80RF LGH-150RVX-E...
Page 188
FILTERS • Advanced high-efficiency filters Optional Filter Lossnay Classifi cation Filter Included Required Model name Applicable model ASHRAE52.2 material piece/set fi lter pieces ISO 16890 (2017) PZ-15RFP LGH-15RVX-E PZ-25RFP LGH-25RVX-E PZ-35RFP LGH-35RVX-E PZ-50RFP LGH-50RVX-E, GUF-50RD4 Synthetic MERV16 PZ-65RFP LGH-65RVX-E fi ber LGH-80RVX-E PZ-80RFP LGH-150RVX-E...
Page 189
The Air Handling Unit Controller is an interface to allow connection to third party manufacturers equipment. Mitsubishi Electric City Multi outdoor units are used with this interface box, creating an ideal solution when a unique air handling unit is required. The Air Handling Unit Controllers are supplied with LEV expansion device(s).
Page 191
The Importance of Control The need for control is paramount in order to optimize the performance of any air-conditioning system and minimize its running costs. Mitsubishi Electric offers a wide range of control options designed to meet such needs. • A Degree of Difference...
Page 192
A wide variety of MELANS products are available to meet all requirements - from the smallest and simplest to the largest and most complex. Mitsubishi Electric offers a wide lineup of individual remote controllers, various centralized controllers, and centralized integrated software, as well as BMS interface hardware and software, etc. Above all, with AE-200E/AE-50E/EW-50E, PC browser and long distance remote control (monitoring and operating) via communication network is possible and easy.
Page 193
FUNCTION TABLE Integrated Communications Control with Mitsubishi Electric's Unique Transmission Network (M-NET) Local remote controller System controller Model PAC- AE-200E + PAR-CT01MAA PAR-40MAA PAR-U02MEDA PAC-YT52CRA PAR-FL32MA PAR-SL100A-E AT-50B AE-200E EW-50E YT40ANRA AE-50E / EW-50E Controllable Groups / Indoors 50 / 50...
Page 194
INDIVIDUAL REMOTE CONTROLLER MA Touch Remote Controller PAR-CT01MAA Multiple color patterns 180 color patterns can be selected for the display's control parameters or background. Language selection Example of system configuration The screen's display language can be selected from 14 languages. English French French...
Page 195
INDIVIDUAL REMOTE CONTROLLER Dual Dual Dual Point Point Point ® ® Bluetooth Bluetooth Connection Connection PAR-CT01MAA-SB PAR-CT01MAA-PB PAR-CT01MAA-S Dimensions: 65(W) x 120(H) x 14.1(D) mm Dimensions: 68(W) x 120(H) x 14.1(D) mm Dimensions: 65(W) x 120(H) x 14.1(D) mm : 2-9/16(W) x 4-3/4(H) x 9/16(D) in. : 2-11/16(W) x 4-3/4(H) x 9/16(D) in.
Page 196
INDIVIDUAL REMOTE CONTROLLER Wired MA Remote Controller (mm) 14.5 • Slim design Compared to the previous remote controller PAR-32/33MAA (PAR-32/33MAA), the latest controller is slimmer by 4.5 mm (depth), allowing for more flexible installation. PAR-40MAA -4.5 mm • Backlit LCD (Liquid Crystal Display) Large, easy-to-see display.
Page 197
INDIVIDUAL REMOTE CONTROLLER ME Remote Controller Brightness sensor • Occupancy sensor Dual Dual Detects vacancy for energy-save control. Point Point • Touch panel & backlit LCD Shows the operation settings screen. When the backlight is off, touching the panel turns on the backlight, Occupancy and it will stay lit for a prespecified period of time.
Page 198
Cool or Heat mode and keep the room temperature within the preset range. *Contact your Mitsubishi Electric sales office for details. • Backlit LCD Backlight for operation in dark places • Flat back...
Page 199
INDIVIDUAL REMOTE CONTROLLER Wireless Remote Controller PAR-FL32MA PAR-SL100A-E PAR-FA32MA (PLFY-P/WL VEM, PLFY-P/WL VFM, PKFY-P/WL VLM/VKM only) Dimensions: 58(W) x 159(H) x 19(D) mm Dimensions: 70(W) x 120(H) x 22.5(D) mm : 2-5/16(W) x 6-5/16(H) x 3/4(D) in. : 2-3/4(W) x 4-3/4(H) x 7/8(D) in. Dimensions: 66(W) x 188(H) x 22(D) mm : 2-5/8(W) x 7-13/32(H) x 7/8(D) in.
Page 200
Cool or Heat mode and keep the room temperature within the preset range. *Contact your Mitsubishi Electric sales office for details. AT-50B Dimensions: 180(W) x 120(H) x 30(D) mm : 7-2/16(W) x 4-3/4(H) x 1-3/16(D) in.
Page 201
Two types of weekly schedules (Summer/Winter) can be set. Today's schedule allows setting of up to 5 patterns. * Depending on the installation conditions, power supply unit (PAC-SC51KUA) is required. Please contact your local distributor or MITSUBISHI ELECTRIC branch office for further information.
Page 202
CENTRALISED REMOTE CONTROLLER Centralised Controller • Promotes energy savings through the comprehensive Dual Dual display of the air-conditioning equipment's energy Point Point consumption. • The energy consumption of the air-conditioning equip- ment can be displayed by individual area in graph form for easy viewing.
Page 203
CENTRALISED REMOTE CONTROLLER • System structure Building management system Tablet Smartphone BACnet ® To be connectable with Wi-Fi Router BACnet ® *1 M-NET M-NET LAN2 LAN1 Group 1 Group 2 AE-200E M-NET LAN1: For air conditioning systems LAN2: For BACnet ®...
Page 204
CENTRALISED REMOTE CONTROLLER Centralised Controller • Main Features Dual Dual Can be used as an expansion controller for the AE-200E Up to 200 indoor units can be operated and monitored by connecting Point Point three EW-50E units to an AE-200E controller. Apportionment of electricity charges The power consumption of each air conditioner can be calculated with an AE-200E controller.
Page 205
CENTRALISED REMOTE CONTROLLER • Manage air conditioner usage conditions Energy consumption of air conditioners can be displayed in an easy-to-understand manner using a web browser. * The billing function requires a PI Controller and watt-hour meter with pulse transmitter (procured locally). •...
Page 206
CENTRALISED REMOTE CONTROLLER ON/OFF Remote Controller Just press a switch to start. All units can be switched ON/OFF by pressing the main switch, and each unit in the group can be switched ON/OFF with individual switches. The PAC-YT40ANRA also has a hardwired connection available (ON/OFF input, fire alarm input, run output, fault output).
Page 207
Dimensions: 116(W) x 90(H) x 40(D) mm : 4-9/16(W) x 3-1/2(H) x 1-9/16(D) in. AHC allows Mitsubishi Electric’s air-conditioning network system (M-NET) to be connected to other systems, which was not possible with the use of ALPHA2 alone. AHC provides the following functions: 1 Controls external devices using the sensor data of air-conditioning units connected to M-NET.
Page 208
CENTRALISED REMOTE CONTROLLER PI Controller The PI controller counts pulses from a power meter, gas meter, water meter, and calorimeter. By combining the AE-200E/AE-50E/EW-50E, the charges for each unit can be calculated and peak cut (e.g., demand control) operations can be performed. The meters can be monitored on the AE-200E/AE- 50E LCD.
Page 209
CENTRALISED REMOTE CONTROLLER DIDO Controller The DIDO controller is used in combination with an AE-200E/AE-50E/EW-50E to operate general-purpose equipment, as well as to monitor operating and error status. It is equipped with two sets of standard terminals (Channels 1 and 2), and four sets of expansion connectors for the input/output terminals.
Page 210
CENTRALISED REMOTE CONTROLLER Open network supported The following options are available to connect CITY MULTI to an open network. ORKS - BACnet ® ORKS LMAP04-E CITY MULTI can be easily combined with a Building Management System (BMS) via L and M-NET Dual Dual ®...
Page 211
CENTRALISED REMOTE CONTROLLER BACnet ® Dual Dual CITY MULTI can be easily combined with a Building Management System (BMS) via EW-50E (AE-200E). BACnet ® an open transmission protocol widely used in BMS and related equipment control. CITY MULTI is compatible with Point Point large-scale BMS management via BACnet...
Page 213
CENTRALISED REMOTE CONTROLLER Optional parts • For CONTROL Model Description Model Description PAC-SE41TS-E Remote Sensor PAC-YG82TB Mounting attachment for AE-200E wall-mount installations PAC-SE55RA-E Remote ON/OFF adaptor for Indoor Unit PAC-YG84UTB Electrical box for AE-200E wall-embed installations PAC-725AD Remote Display Adaptor for Indoor Unit PAC-YG86TK Mounting kit for AE-200E wall-mount installations PAC-SC37SA-E...
Page 214
ot Water Solution/ Air to Water Series...
Page 215
Air to Water Series is a system that can create cold and hot water and be used with a VRF system as with the indoor units. It can supply hot water of up to 70ºC, and can be used in any situation, such as for showers or floor heating in homes and hotels, as well as for supplying hot water in offices and restaurants.
Page 216
FEATURES ATW Unit - Booster Unit PWFY-P100VM-E-BU Benefiting from the heat recovery operation of the CITY MULTI R2/WR2 system, the booster unit converts energy from the air to higher temperatures suitable for supplying hot water with virtually no wasted energy. Connectable to Applications Operation...
Page 217
FEATURES ATW Unit - HEX Unit PWFY-EP100VM-E1-AU By utilizing waste heat from the R2/WR2 Series for heating operation in the HEX unit, hot water can be supplied highly efficiently. Also, when connected with the Y/WY Series, it provides higher efficiency operation compared to a conventional system. Connectable to Applications Operation...
Page 218
FEATURES • System outline of the HEX unit with Y-Series The HEX unit is connected to the Y outdoor OUTSIDE MACHINE ROOM INDOOR unit with refrigerant pipes and to the water tank with water pipes. It is not equipped with a compressor.
Page 219
Air to Water system+CITY MULTI+OA processing unit. With the combination of Mitsubishi Electric’s product lineup, the system can provide hot water without a boiler and air conditioning with a high COP. What’s more, with the OA processing unit in the system, suitable...
Page 220
FEATURES APPLICATION EXAMPLE The application examples here indicate why ATW systems are chosen and how the great potential offered by using ATW systems can be best utilized. RESTAURANTS Reason for ATW >Hot water is almost always required in the kitchen. >Waste heat from the kitchen can be used to cool the dining hall in the summer and increase efficiency of the system.
Page 221
- It may also be in violation of applicable laws. - MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong type of refrigerant. *3These values are based on Regulation (EU) No.517/2014.
Page 222
SPECIFICATIONS HEX unit Solenoid valve is not installed PWFY-EP100VM-E1-AU Model PWFY-EP100VM-E1-AU Power source 1 - phase 220 - 230 - 240V 50 / 60Hz Heating capacity (Nominal) 12.5 kcal / h 10,800 BTU / h 42,700 Power input 0.015 Current input 0.068 - 0.065 - 0.063 Outdoor temp.
SPECIFICATIONS Remote Controller PAR-W21MAA : Each group : Not available Item Description Operations Display ON / OFF ON and OFF the operation of a group of units Operation mode switching Switches between Hot Water / Heating / Heating ECO / Anti - freeze / Cooling * Available operation modes vary depending on the unit to be connected.
Page 225
Note: When you intend to adopt PWFY-EP100VM-E1-AU with above system configuration, you may need to use optional part (PAC-SV01PW-E). Please contact your Mitsubishi Electric sales office for details. PAC-SV01PW-E Model 1 - phase 220 - 230 - 240V 50 / 60Hz...
Page 226
HOT WATER HEAT PUMPS QAHV Hot Water Heat Pump Series As a leading manufacturer of air-to-water heat pumps, Mitsubishi Electric have developed QAHV; the latest innovation in their comprehensive lineup of Hot Water Heat Pump products. QAHV has been specifically designed to produce high volume hot water and is suitable for commercial and industrial applications where hot water demand is high.
Page 227
Mains (optional) Water Mitsubishi Electric Patented Twisted and Spiral Gas Cooler Using twist pipes as water pipes and running the refrigerant pipes along their grooves helps to increase the heat-conductive area, allowing for better heat transfer. Twisted water pipe with the refrigerant pipe...
Page 228
“Capacity Priority“ mode through the dry NC-contact. Type Inverter scroll hermetic compressor *Due to continuing improvements, specifications may be sub- Maker MITSUBISHI ELECTRIC CORPORATION ject to change without notice Compressor Motor Output 11.0 *Do not use steel pipes as water pipes.
Page 229
HOT WATER HEAT PUMPS Air Source Heat Pump CAHV-P500YB-HPB Heat Pump System Heat Source from outdoor air Heat Heat Heat Heat Heat Heat Heat Input energy Tank Input energy Heat from Output energy outdoor air Heat Heat Heat Heat Heat Heat Heat For hot water...
Page 230
HOT WATER HEAT PUMPS 70ºC *COP 4.13 High temperature Over 4* Outdoor temp.: 7ºC DB/ 6ºC WB Outlet water temp.: 35ºC A "Flash Injection Circuit," which is designed for our ZUBADAN CITY MULTI air conditioning system for cold regions, is incorporated in our new hot water heat pump. Through utilizing this advanced "Flash Injection Circuit" and the latest high-efficiency compressor, the hot water heat pump is able to provide hot water of 70°C with the use of R407C and with better retention of capacity at low outdoor temperatures.
Page 231
HOT WATER HEAT PUMPS Ground Source Heat Pump CRHV-P600YA-HPB Heat Pump System Heat Heat Input Heat Heat Pumps up Heat energy Source from the ground Tank Heat Heat Heat Input energy Heat from Output energy ground source Heat Heat Heat Heat Heat Heat...
Page 232
HOT WATER HEAT PUMPS Support for system renewal Since the CRHV model is inverter-controlled, the unit-side capacity Capacity Capacity can be adjusted to suit the existing bore hole heat quantity (demand 60kW 45kW control). 65ºC SCOP *SCOP 4.33 High temperature Over 4* Brine outlet temp.: -3ºC Outlet water temp.: 35ºC...
Page 233
Water side stainless steal plate and copper brazing Air side Plate fin and copper tube Type Compressor Inverter scroll hermetic compressor Maker MITSUBISHI ELECTRIC CORPORATION Starting method Inverter Motor output 7.5 × 2 Case heater 0.045 × 2 Lubricant MEL32 Air flow rate...
Page 234
Hot water side stainless steel plate and copper brazing Heat source side stainless steel plate and copper brazing Compressor Type Inverter scroll hermetic compressor Maker MITSUBISHI ELECTRIC CORPORATION Starting method Inverter Case heater 0.035 × 2 Lubricant MEL32 Protection High pressure protection High pres.Sensor &...
Page 235
SPECIFICATIONS PAR-W21MAA Specifications [CAHV-P500YB-HPB] Item Description Operations Display ON/OFF Runs and stops the operation of a group of units Operation mode switching Switches between Hot Water / Heating / Heating ECO / Anti-freeze / Cooling * Available operation modes vary depending on the unit to be connected. * Switching limit setting can be made via a remote controller.
nstallation Information * Refer to the enclosed Installation Manual for details on installation. Arrange to have an expert install the system correctly. 1. General precautions 1-1. Usage ♦The air-conditioning system described in this catalogue is designed for human comfort. ♦This product is not designed to assist in the preservation of food, provide conditions to maintain plants or animals, or stabilize environments for the preservation of precision equipment or art objects.
Page 237
♦Ensure that there is enough space around each unit. 1-7. Optional accessories ♦Only use accessories recommended by Mitsubishi Electric. Consult your local distributor or a qualified technician when installing them. Improper installation by an unqualified person may result in water leakage, power leakage, system breakdown, or fire.
Page 238
Installation Information 2. Precautions for Indoor unit, HBC controller, and BC controller 2-1. Operating environment ♦The refrigerant (R410A) used in the air conditioner is non-toxic and nonflammable. However, if the refrigerant leaks, the oxygen level may drop to harmful levels. If the air conditioner is installed in a small room, measures must be taken to prevent the refrigerant concentration from exceeding the safety limit even if the refrigerant leaks.
Page 239
Installation Information 2-4. Noise level (Sound pressure level) ♦The sound pressure level is a value measured in an anechoic room in accordance with the conventional method in JIS standard. The sound pressure level actually measured at the installation site is usually higher than the value indicated in this catalogue due to the influence of ambient noise and echoes.
Page 240
Installation Information 3. Precautions for fresh air intake-type indoor unit 3-1. Usage ♦The fresh air intake-type indoor unit is designed to supply pretreated outside air into the room. Do not use to handle internal thermal load. 3-2. Unit characteristics For PEFY-P-VMH-E-F and PEFY-P-VMHS-E-F ♦This unit cannot perform drying operation.
Page 241
Installation Information ♦Outside air is directly supplied into the room during Thermo OFF. Be careful with regard to cold supply air due to low outside air temperatures and of condensation in the room due to high humidity of the outside air. ♦If the airflow rate is higher than the usable range, condensation may drip from the air outlet, and the air flow rate will be automatically reduced by the fan motor control.
Page 242
Installation Information ♦The salt-resistant unit is resistant to salt corrosion, but not salt-proof. Please note the following when installing and maintaining outdoor units in a marine environment. 1. Install the salt-resistant unit in an area in which it is not directly exposed to sea breezes, and minimize exposure to salt water mist.
Page 243
Installation Information 4-5. Noise level (Sound pressure level) ♦The sound pressure level is a value measured in an anechoic room in accordance with the conventional method in JIS standard. The sound pressure level actually measured at the installation site is usually higher than the indicated value in this catalogue due to the influence of ambient noise and echoes.
Page 244
Installation Information ■PUMY-SP-VKMD-A(-BS), PUMY-SP-YKMD-A(-BS) PUMY-P-VKM4/5(-BS), PUMY-P-YKMD-A(-BS) PUMY-SP80, 112, 125, 140VKMD-A(-BS) PUMY-P112, 125, 140VKM5/YKM4(-BS) PUMY-SP80, 112, 125, 140YKMD-A(-BS) PUMY-P200YKMD-A(-BS) Microphone Microphone Unit Unit 1.5m 1.5m Ground Ground...
Page 245
Installation Information 5. Precautions for control-related items 5-1. Product specification ♦To introduce the MELANS system, a consultation with us is required in advance. Especially to introduce the electricity charge-apportioning function or energy save function, further detailed consultation is required. Consult your local distributor for details. ♦Billing calculation for AE-200E/AE-50E/EW-50E, or the billing calculation unit is unique and based on our original method.
aintenance Equipment Maintenance cycle [Note that maintenance cycle does not mean guarantee period.] The following tables are applicable when using equipment under the conditions below. Normal use without frequent START/STOPs (The number of START/STOPs is assumed to be less than 6 times per hour in normal use.) Operating hours are assumed to be 10 hours per day/2500 hours per year.
Page 247
B.S. Salt Protection Specifications City Multi VRF Outdoor Units PUHY, PURY YNW-BS Paint thickness Name Base material Surface treatment Salt Standard damage protection External Internal Alloyed galvanized • • Bottom frame Polyester resin coating 70μm or more 70μm or more sheet Front panel Galvanized sheet...
Page 248
Phone 03 341 2837 Be sure to ask for Mitsubishi Electric | Other brands share the 3-diamond logo, however they are separate to the Mitsubishi Electric brand and cannot supply the models, features or guarantees outlined in this brochure. | All models, features and specifications are subject to change and amendment at anytime | PRINTED AUG 2021...
Need help?
Do you have a question about the Y Series and is the answer not in the manual?