KB1 type
CMB-M V-KB1
Model
Number of branch
Power source
Cooling
kW
Power input
(220/230/240)
Heating
kW
Cooling
Current input
(220/230/240)
Heating
External finish
Connectable Main BC controller
The maximum number of connectable
Sub BC controllers
The maximum connectable capacity of
indoor units
External dimension HxWxD
mm
in.
Refrigerant piping diameter
To outdoor/heat source unit
Connectable unit capacity
-
mm(in.) O.D.
To indoor unit
mm(in.) O.D.
To other BC controller
Total down-stream Indoor unit
capacity
to P200
mm(in.) O.D.
P201 to P300
mm(in.) O.D.
P301 to P350
mm(in.) O.D.
P351 to P400
mm(in.) O.D.
P401 to P600
mm(in.) O.D.
P601 to P650
mm(in.) O.D.
P651 to P800
mm(in.) O.D.
P801 to P1000
mm(in.) O.D.
P1001 or above
mm(in.) O.D.
Field drain pipe size
mm (in.)
Net weight
kg (lbs)
Sound power level
Rated operation dB <A>
(measured in anechoic
Defrost
dB <A>
room)
Sound pressure level
Rated operation dB <A>
(measured in anechoic
Defrost
dB <A>
room)
*14
Accessories
Notes:
1.Installation/foundation work, electrical connection work, insulation work, power source
switch, and other items shall be referred to the Installation Manual.
2.The equipment is for R410A refrigerant.
3.Install this product in a location where noise (refrigerant noise) emitted by the unit will
not disturb the neighbors.
(For use in quiet environments with low background noise, position the BC
CONTROLLER at least 5m away from any indoor units.)
4.Sound pressure/power level differs depending on the connected outdoor/heat source
unit capacity or operation condition.
The sound pressure/power level at the rated operation is the value of the cooling
mode.
5.The sound pressure/power level values were obtained in an anechoic room. Actual
sound pressure level is usually greater than that measured in anechoic room due to
ambient noise and deflection sound.
CMB-M104V-KB1
4
50 Hz
0.060/0.068/0.076
0.030/0.034/0.038
A
0.28/0.30/0.32
A
0.14/0.15/0.16
Galvanized steel plate (Lower part drain pan: Pre-coated galvanized sheets + powder coating)
250 x 596 x 476
9-7/8 x 23-1/2 x 18-3/4
High press. pipe
-
Liquid pipe
Indoor unit Model 50 or smaller
Indoor unit Model 50 or smaller
6.35 (1/4) Brazed
12.7 (1/2) Brazed
bigger than 50 15.88 (5/8)
bigger than 50 9.52 (3/8) Brazed
Brazed (19.05 (3/4), 22.2 (7/8)
with optional joint pipe used.)
High press. pipe
Liquid pipe
15.88 (5/8) Brazed
9.52 (3/8) Brazed
19.05 (3/4) Brazed
9.52 (3/8) Brazed
19.05 (3/4) Brazed
12.7 (1/2) Brazed
22.2 (7/8) Brazed
12.7 (1/2) Brazed
22.2 (7/8) Brazed
15.88 (5/8) Brazed 28.58 (1-1/8) Brazed
28.58 (1-1/8) Brazed 15.88 (5/8) Brazed 28.58 (1-1/8) Brazed 28.58 (1-1/8) Brazed 15.88 (5/8) Brazed 28.58 (1-1/8) Brazed
28.58 (1-1/8) Brazed 19.05 (3/4) Brazed 34.93 (1-3/8) Brazed 28.58 (1-1/8) Brazed 19.05 (3/4) Brazed 34.93 (1-3/8) Brazed
28.58 (1-1/8) Brazed 19.05 (3/4) Brazed
34.93 (1-3/8) Brazed 19.05 (3/4) Brazed
O.D. 32 (1-1/4)
23 (51)
59
71
40
53
1-phase 220-230-240 V
60 Hz
50 Hz
0.048/0.054/0.060
0.119/0.135/0.151
0.024/0.027/0.030
0.060/0.068/0.076
0.22/0.24/0.25
0.55/0.59/0.63
0.11/0.12/0.13
0.28/0.30/0.32
CMB-M108/1012/1016V-JA1, CMB-P1016V-KA1
11
P350 for each
Low press. pipe
High press. pipe
-
-
Gas pipe
Liquid pipe
Indoor unit Model 50 or smaller
6.35 (1/4) Brazed
bigger than 50 9.52 (3/8) Brazed
Low press. pipe
High press. pipe
19.05 (3/4) Brazed
15.88 (5/8) Brazed
22.2 (7/8) Brazed
19.05 (3/4) Brazed
28.58 (1-1/8) Brazed 19.05 (3/4) Brazed
28.58 (1-1/8) Brazed
22.2 (7/8) Brazed
22.2 (7/8) Brazed
41.28(1-5/8) Brazed 28.58 (1-1/8) Brazed 19.05 (3/4) Brazed
41.28(1-5/8) Brazed 34.93 (1-3/8) Brazed 19.05 (3/4) Brazed
Drain Connection pipe, Washer, Tie band
6.The sound pressure level values were obtained at the location below 1.5m from the unit.
7.The solenoid valve switching sound is 56 dB (sound pressure level) regardless of the unit
model.
8.Indoor units P100, P125, P140 can be connected to 1 branch. (In this case, cooling
capacity decrease a little.)
9.Refrigerant piping diameter for connection of plural indoor units with 1 branch shall be
referred to the Installation Manual.
10.This unit is not designed for outside installations.
11.When brazing the pipes, be sure to braze after covering a wet cloth to the insulation pipes
of the units in order to prevent it from burning and shrinking by heat.
12.Can't use singleness. (MAIN BC CONTROLLER is necessary)
13.The ambient relative humidity of the BC controller needs to be kept below 80%.
14.The sound pressure level measured by the conventional method in JIS for reference
purpose.
SPECIFICATIONS
CMB-M108V-KB1
8
60 Hz
0.096/0.108/0.119
0.048/0.054/0.060
0.44/0.47/0.50
0.22/0.24/0.25
250 x 596 x 476
9-7/8 x 23-1/2 x 18-3/4
Low press. pipe
-
Gas pipe
Indoor unit Model 50 or smaller
12.7 (1/2) Brazed
bigger than 50 15.88 (5/8)
Brazed (19.05 (3/4), 22.2 (7/8)
with optional joint pipe used.)
Liquid pipe
Low press. pipe
9.52 (3/8) Brazed
19.05 (3/4) Brazed
9.52 (3/8) Brazed
22.2 (7/8) Brazed
12.7 (1/2) Brazed
28.58 (1-1/8) Brazed
12.7 (1/2) Brazed
28.58 (1-1/8) Brazed
15.88 (5/8) Brazed 28.58 (1-1/8) Brazed
41.28(1-5/8) Brazed
41.28(1-5/8) Brazed
O.D. 32 (1-1/4)
31 (69)
59
71
40
53
111