Low noise type
PEFY-P VMR-E-L/R
• Realizes low noise operation. Most suitable for places such
as hotels where low noise operation is required.
• The position of the inlet can be selected to be at the bottom
or rear.
• The location of the piping connection can be selected
according to the layout of a room.
Static pressure
Low
5 Pa
noise
Piping connection
Air flow rate
Right/Left
3 levels
Low static pressure type
PEFY-P VMS1(L)-E
• Thin design with a body height of 200 mm (all HP models)
enables installation in a ceiling with small cavity space.
• Realizes low noise operation.
• Demonstrates a maximum external static pressure of 50 Pa
despite its compact design.
• The drain pump can be installed or not.
Static pressure
Low
Maximum 50 Pa
noise
Drain pump (standard) Maximum lifting height 550 mm
*For PEFY-P VMS1-E
High static pressure type
PEFY-P VMHS-E
• Maximum external static pressure of 250 Pa* allows for
more flexibility in duct design.
*P200, P250VMHS-E models
• Compatible with drain pumps (option) 550 mm−700 mm
Static pressure Maximum 250 Pa
*Maximum pressure differs depending on model.
Drain pump (option)
Maximum lifting height 700 mm
PEFY-P VMX(L)-E(1)
P.130
• Measures only 450 mm* in depth and 200 mm in height.
Installable in a limited space such as in a room with a clipped
ceiling.
*Duct flange and filter are excluded.
• Three return air intake positions (side, bottom, side bottom)
to choose from to suit the installation conditions.
Static pressure Maximum 45 Pa
*Maximum pressure differs depending on model.
Rear inlet
Depth: 450 mm* Height: 200 mm
Bottom inlet
*Duct flange and filter are excluded.
Drain pump (standard)* Maximum lifting height 700 mm
Medium static pressure type
PEFY-P VMA(L)-E
P.134
• Thin design with a body height of 250 mm (all HP models)
enables installation in a ceiling with small cavity space.
• The position of the inlet can be selected to be at the bottom or rear.
• Demonstrates a maximum external static pressure of 150 Pa
despite of its compact design.
• The lineup consists of two types of models, with or without a
built-in drain pump, for more flexibility in piping layout design.
Height
Static pressure Maximum 150 Pa
200 mm
*Maximum pressure differs depending on model.
Air flow rate
Drain pump (standard) Maximum lifting height 700 mm
3 levels
PEFY-P VMHS-E-F
P.139
PEFY-P VMH-E-F
• Outlet air temperature can be controlled. (VMHS-E-F model only)
• Fresh air intake type indoor unit
• Maximum external static pressure of 250 Pa* allows for
more flexibility in duct design.
*VMHS-E-F model
Static pressure Maximum 250 Pa
*Maximum pressure differs depending on model.
Air flow rate
Drain pump (option) Maximum lifting height 700 mm
3 levels
Compact depth type
*For PEFY-P VMX-E(1)
Height
250 mm
*For PEFY-P VMA-E
Fresh air intake type
Air flow rate 3 levels
*For PEFY-P VMHS-E-F
129
P.132
3 inlet type
Air flow rate
3 levels
P.136
Rear inlet
Bottom inlet
Air flow rate
3 levels
P.143
Fresh air
intake type
*For PEFY-P VMHS-E-F