Ceiling cassette type
4-way airflow type
PLFY-P VEM-E/A
• Technologies and functions
Optional
3D i-see Sensor and versatile airflow variation provide
comfort to all corners of the room.
Optimum airflow
2-, 3-, 4-way airflow pattern
selection
Three outlet options are
available--bidirectional, three-way,
and four-way--to suit different types of
installation. Select, for example, the
four-way pattern for installation in
the center of the room and three-way
pattern for installation in the corner.
2-, 3-, 4-way airflow pattern
selection
* Optional shuffle placement is required
for 2- and 3-way patterns.
Equipped with high- and low-ceiling modes
Units are equipped with high- and low-ceiling operation modes that make it possible to switch the airflow volume to match the height of
the room. Being able to choose the optimum airflow volume helps optimize the breezy sensation felt throughout the room.
*P100
*
4.5 m
4-way airflow with
4-way airflow with
high-ceiling setting
standard setting
Automatic air-speed adjustment
An automatic air-speed mode automatically adjusts airflow speed to maintain comfortable room conditions at all times. This setting
automatically adjusts the air speed to conditions that match the room environment.
Strong
∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ P.167
Individual vane angle
settings
Vane direction can be changed or
fixed from the remote controller to
direct the supply air at or away from
objects or occupants in the room.
The airflow direction of each vane
can be set using the wired remote
controller or wireless remote
controller (PAR-SL100A-E).
Horizontal
Downward
*
*
2.7 m
3.2 m
4-way airflow with
low-ceiling setting
At the start of the
heating/cooling operation,
airflow is set to high speed
to quickly heat/cool the
room.
Optional
Multi-directional
air conditioning
airflow pattern selection
individual vane angle settings
Combinations with individual vane settings
enable an optimal outlet setting for each
room layout to ensure even temperature
distribution throughout each room. The
result is uniformly comfortable air
Adjustable
conditioning.
Airflow range
P20–P80
Model
High-ceiling
Low-ceiling
Airflow
Standard
pattern
setting
setting
setting
3.5
2.5
2.7
4-way
m
m
3.5
3.0
2.7
3-way
m
m
3.5
3.3
3.0
m
m
2-way
Gentle
2-, 3-, 4-way
P100/P125
High-ceiling
Low-ceiling
Standard
setting
setting
setting
4.5
2.7
3.2
m
m
m
m
4.5
3.6
3.0
m
m
m
m
4.5
4.0
3.3
m
m
m
m
When the room temperature
reaches the desired setting, the
airflow speed is automatically
decreased for stable and
comfortable heating/cooling
operation.