Notes:
Cabinets loaded by Ethernet port 1 ≥ cabinets loaded by Ethernet port 2 ≥ ... ≥ cabinets loaded by
Ethernet port 10
The number of cabinets loaded by each Ethernet port must be an integer multiple of Cabinet Row Qty or
Cabinet Column Qty of the screen.
The total pixels of the cabinets loaded by Ethernet port 1 cannot exceed 650,000.
Step 4 Rotate the knob to select Data Flow (Front View) and press the knob to confirm. Select a physical connection
for the cabinets.
During data flow settings, you can see the result on the LED screen in real-time. If the entire screen displays
content correctly, that is, no overlapping or repetition, press the knob to save the settings.

5.2.2 Send Cabinet Configuration File

After the LED screen is powered on, if a cabinet or the whole LED screen can not be lit, you can update the
configuration file in the cabinet and re-light the cabinet by using this function. Then you can perform the
screen configuration and the screen can display the output image as usual.
The cabinet configuration file is a file with the suffix ".rcfgx", which stores the module, cabinet, data flow
information and more.
Add Cabinet Configuration File
Step 1 Run the NovaLCT software. On the menu bar, go to User > Advanced Synchronous System User Login.
Figure 5-5 Log in to NovaLCT
Step 2 Go to Tools > Controller Cabinet Configuration File Import to enter the controller cabinet configuration file
importing page.
www.novastar.tech
VX1000 All-in-One Controller User Manual
12