Mapping - NovaStar VX1000 User Manual

All-in-one controller
Table of Contents

Advertisement

Figure 5-7 Advanced configuration
Step 3 Select the desired Ethernet port.
Step 4 Set the row and column quantities of the cabinets loaded by the current Ethernet port.
Step 5 Set the horizontal and vertical offsets of the first cabinet loaded by the current Ethernet port.
The offset value indicates the distance between the top left corner of the cabinet and the top left corner of the
whole screen. The offset value unit is pixel.
Step 6 Select the desired data flow for the cabinets.

5.2.5 Mapping

Mapping is used to show the relations between the cabinets of the LED screen and the sending devices so
that you can view or check the connections between the cabinets.
Note:
The receiving cards that are connected to the device must support the Mapping function. For the supported
models of the receiving cards, please visit our official website at www.novastar.tech.
On the main menu screen, go to Screen Configuration > More Settings > Mapping and turn on the function.
Figure 5-8 Mapping
P:05 indicates the Ethernet port number of the sending device.
#001 shows the number of the cabinet loaded by the Ethernet port.
www.novastar.tech