The Extension terminal may be useful for the following situation.
 If the Door Contact cannot be mounted on the door frame, you can connect an additional extension switch to the extension terminal to mount the
Door Contact remotely.
 Any dry contact device with N.C. (Normal Close) loop can be connected to the Extension Terminal making the Door Contact serve as an Universal
Transmitter.
 Multiple dry contact device can be wired together with Door Contact, as show in diagram below.
N
O
T
E
>
>
N
O
T
E
>
>
If both the Internal Magnet Switch and Extension Terminal operate together, then
 When the protected door is opened/closed or the external device is triggered, the Door Contact activates and transmits a signal
immediately .
 However, the Door contact will only transmit a Door Closed or Restored signal after both the door and the external device are restored for
3 sec.

10 SPECIFICATIONS

Model
Frequency
Power source
Battery life
Operating conditions
Weight
11 DIMENSIONS
32
GEN-DC
433.82 MHz
CR2 Lithium battery
Approx. 6 years (20 activations per day, 25°C)
-10°C to +45°C (up to 85% non-condensing)
50 g (including battery)
21
16.7
10.5
12
Unit: mm